DUCTING TO HVAC SYSTEMS
8
CAUTION!
PLEASE NOTE: RETURN TO RETURN INSTALLS ARE TO BE CONSIDERED LAST RESORT OPTIONS AND
ARE NOT RECOMMENDED. THE DEHUMIDIFIER WILL HEAT THE AC COOLING COILS WHICH DIMINISHES
THE AMOUNT OF WATER THE AC SYSTEM WILL REMOVE WHEN OPERATING. IF THIS INSTALLATION IS
CHOSEN, THE DEHUMIDIFIER MUST ACTIVATE THE HVAC BLOWER AND AC CALLS NEED TO LOCK OUT THE
DEHUMIDIFIER FROM RUNNING. PLEASE CHECK YOUR LOCAL CODES PRIOR TO INSTALLING.
c. Dedicated Ultra Series Return to HVAC Return
Create a separate return for the Ultra
Series Dehumidifier in a central area
of the building.
Installing the supply air from the Ultra
Series Dehumidifier to the return of
the HVAC system requires the HVAC
fan to run when the Ultra Series
Dehumidifier is operating.
d. HVAC Return to HVAC Return
If Check Damper is not in place, the
HVAC fan must turn on when the
dehumidifier is in operation.
e. No Existing Ductwork Installation
When installing the Santa Fe Ultra Series Dehumidifier in a structure that does not have a forced air HVAC
system, a single return for the dehumidifier should be installed in a central location.
Install an insulated duct from outside to the 6" collar of the Santa Fe Ultra Dehumidifier to provide outdoor air
ventilation (optional).
The supply of the Ultra Series Dehumidifier should be ducted to the rooms in the home that have the ductless
mini-split heads and as close to the heads as possible. Be sure to utilize multiple rooms to allow air inside the
structure to properly circulate. Proper air distribution is important to ensure even humidity control and heat
distribution throughout the structure.
A 6" diameter duct is recommended for branches to bedrooms. An 8" diameter duct is recommended for
branches to larger areas.
DO NOT locate return in a bathroom or
kitchen.
DO NOT locate the supply in rooms
where doors may be closed.
Control should be located remotely
from the dehumidifier and placed in a
central location.
14
Santa Fe ULTRA155/205 Installation & Operation Instructions
Motorized
Damper
Optional Outdoor
Air Intake
HVAC Return
Motorized
Damper
Optional Outdoor
Air Intake
Optional Outdoor
Air Intake
Ultra Series
Indoor Air
Return
Air Handler
HVAC
Return
Ultra Series
Supply
Ultra Series
Optional Check Damper
(no HVAC fan needed)
Indoor Air Return
Ultra Series
Supply
Motorized
Damper
Ultra Series
Supply
Santa-Fe-Products.com | 800.533.7533
HVAC Supply
Air Handler
HVAC
Supply