12
CONTROLS
The Santa Fe Ultra70 features a built-in dehumidistat control as well as the ability to wire a separate remote mounted
control to the unit.
If using the built-in dehumidistat to control the unit, locate the unit in an location where it can accurately sense the
humidity of the area where humidity control is desired. Adjust the humidity control so that the unit maintains the
desired level of humidity.
If the Santa Fe Ultra70 is located outside of the area where humidity control is desired, consider using a remote wired
humidity controller that is located in the area where humidity control is desired. In this configuration the built in
dehumidastat should be set to off. Santa Fe offers the DEH 3000 proprietary remote mounted control. The DEH 3000
monitors and controls relative humidity and proper ventilation levels in their home. This control is also available in a
version that has remote sensing capability called the DEH 3000R.
NOTE: The DEH 3000 is sold separately. Other thermostats are compatible with the Santa Fe Ultra70.
1. Wiring Controls
CAUTION!
DO NOT ALLOW THE 24V TERMINAL FROM THE SANTA FE ULTRA70 TO CONTACT THE COM
TERMINAL ON THE SANTA FE ULTRA70 OR DAMAGE TO THE TRANSFORMERS WILL RESULT.
a. Circuit Breaker
To prevent damage to the 24 volt control transformer, the Santa Fe Ultra70 comes with a resettable circuit
breaker. Check wiring for any electrical short and repair before resetting breaker. Resetting the circuit breaker
without correcting the electrical short may result in transformer damage. Be sure to check the electrical
schematic in this manual or inside the access panel of the Santa Fe Ultra70 before making any control
connections. The reset button for the circuit breaker can be found on the back of the unit.
b. Control Connections
The control and the Santa Fe Ultra70 are labeled to prevent confusion. Depending on the control, some of the
screw terminals on the Santa Fe Ultra70 may not be used. Be sure to consult the electrical schematic in this
manual or inside the access panel of the Santa Fe Ultra70 before making control connections.
800.533.7533 | Santa-Fe-Products.com
Rear View
Circuit Breaker Reset Button
Santa Fe ULTRA70 Installation & Operation Instructions
19