Dirt Receptacle
occasional maintenance of the dirt receptacle is necessary to ensure constant,
lasting performance. We recommend that it be emptied at least every season,
depending on frequency of use. to empty the collector dust receptacle, disconnect
your HD motor from its power source. then, release the two clamps and empty
the recipient. reseal the receptacle in place.
Collector with Filters
regular maintenance of the filtration system is
recommended to ensure maximum performance of your
central vacuum system.
your cyclo Vac system collector is equipped with two
filters. the anti-clogging filter (thin fabric) stops the larger
particles, and the thick filter catches the microscopic
particles. Both filters are washable in cold water (no
bleach) and can be dried at low temperature.
1. to remove the filters, first remove the dust receptacle
(figure 13).
2. then, use the straps at the base of the filters to
withdraw (figure 14) We recommend cleaning the anti-
clogging filter (thin fabric) every time the dust receptacle
is emptied. you may either shake it out, or wash it. the
thick filter should be cleaned after four anticlogging filter
cleanings, or approximately once a year.
3. Both filters must be completely dry before they are
reinstalled. carefully install them in the support grooves
(figure 15) on the filter frame to ensure adequate
protection of the motor. Install the thick filter first,
and the anticlogging filter (thin fabric) over.
Inspect the filters for tears and punctures before
reinstalling them. Do not reinstall damaged filters.