4 - LIGHTING AND REGULATING
COMBUSTION
OPEN
Follow the instructions below to regulate combustion:
Move the regulation valve from right to left to
provide a greater inflow of air to favour combustion
(FIG. 7).
When lighting, we recommend moving the
combustion regulation valve completely to the left.
It is essential to provide an abundant load of fuel when
lighting. The following loads will depend on the heat
requirement desired.
EIt is advisable to leave the door partially open to
avoid condensation and to keep the glass clean for
some minutes after lighting the fire.
Once the fireplace is working at its normal level and the
chimney has heated up, regulate combustion by means
of the regulation valve. When the inflow of air is fully
closed, combustion will be slow; when the inflow of air
is open, combustion will be more intense.
For the best performance from your appliance, place
the combustion regulation valve in the central
position.
Actuating the control valve as described in the previous
steps, provides a greater inflow of air for the
combustion process; this provision of air takes place at
the height of the andiron and the upper part of the
glass. This will contribute to the dual purpose of
keeping the glass clean and facilitating the lighting up
process. Check when loading that the air inlet at the
height of andiron is free from ashes. Otherwise, clean
it to provide a proper combustion process.
CLOSE
FIG. 7
ATTENTION! When working, the metal parts of the
fireplace may reach high temperatures. Protect your
hands with a fireproof glove when touching the said
parts.
The air-inlet cut off plate is necessary to obtain the
results accredited by the Official laboratory that has
tested this product. To remove the air-inlet cut off plate,
first remove the bottom plate, the vermiculite starting
from the sides and the back, the lower and upper baffle.
Remove the airinlet cut off plate by lifting and turning
90 degrees, and then put the baffles back on, the rear
and side ones, and the bottom plate. See the section 7.
If the compact fireplace is used in a room together with
other heating appliances that also need air for
combustion purposes, it is advisable to prepare an
additional air intake of outside air to facilitate the said
combustion processes.
22
Air-inlet cut-off
plate
Air-inlet cut-off
plate
FIG. 8