M5xL200 Flange
long Bolt
Battery Control Unit
Spacer
Battery Control Unit
Spacer
21
7. Loosen six (6) M6 bolts and
disassemble Standing Bracket #2
Bracket #1 from the wall.
8. Loosen six (6) long bolts.
9. Re-attach the top cover.
* Tighten the M5xL65 Flange
Bolt (4ea) with a torque of
5N·m(3.7lbf·ft).
10.
Battery Modules.
* Be careful not to pull the cables
tight by lifting the Battery Control
Unit excessively. It may damage the
cables or disassembly of connector.
11. After that, place the second spacer on
top of the Battery Modules.
F r o
n t
F r o
n t
Power connector
3
1
TPA
2
Sensing connector
1
1
2
3
Module Support BRKT
Wall Mounting Bracket
Bottom View
12. Disconnect the power and sensor
connectors on the right and left sides
(2 each). This step should undergo
a deliberate visual inspection by the
installer before proceeding.
1) Power connector: 1 Pull the TPA
and 2 press the button at the
center of the connector. Then 3
pull out the connector vertically.
2) Sensor connector: 1 Push in the
sides of the connector and 2 pull
out the connector vertically. Then
3 pull the connector out to the
side of the Battery Module.
* Be careful not to damage to the
sensor connector's guide pins
during disassembly.
* At this stage, DO NOT lift the
Battery Control Unit until all
connectors are disconnected.
13. Disassemble Module Support BRKTs
with six (6) bolts each.
* Loosen the M6 Flange Bolts (x12)
14. Repack the Battery Modules.
15.
Loosen eight (8) M8 sems bolts and
remove the Module Connect Plate.
Then remove the Wall Mounting
Bracket.
16. Repack all remaining parts.