Global Industrial 292853 Manual Del Usuario página 4

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Electronic Control Panel & Remote Control
Note: This display shows the room temperature in Fan
Mode except when setting the Timer.
1
9
8
7
Air Conditioner Controls
Fig. 4
Normal Operating Sounds
• You may hear a pinging noise caused by water hitting
the condenser on rainy days, or when the humidity is
high. This design feature helps remove moisture and
improve efficiency.
• You may hear the thermostat click when the compressor
cycles on and off.
• Water will collect in the base pan during rain or days of
high humidity. The water may overflow and drip from
the outside part of the unit.
• The fan may run even when the compressor is not on.
1. Digital Display: Without the timer setting, the operation mode
is Cooling, Dry, Fan and Auto, and the set temperature will be
displayed. Time will be displayed under the timer setting.
and
Buttons: Use these buttons on the control panel
2.
and remote to increase or decrease the Set Temperature or
Timer. Temperature range: 61 ~ 88 or 16 ~ 31.
3. Power Button: Turn the air conditioner on and off.
4. Mode Button: Press the mode button to cycle through the
various modes: Cool, Dry, Fan and Auto, or Heat.
Cool Mode: The cooling function allows the air conditioner
to cool the room and at the same time reduces air humidity.
Press the MODE button to activate the cooling function.
To optimize the function of the air conditioner, adjust the
temperature and the speed by pressing the button indicated.
Dry Mode: This function reduces the humidity of the air to
make the room more comfortable. Press the MODE button
to set the DRY mode. An automatic function of alternating
cooling cycles and air fan is activated.
Fan Mode: The conditioner works in only ventilation. Press
the MODE button to set the FAN mode. With pressing the
FAN SPEED button the speed changes in the following
sequence: Hi, Med and Lo in FAN mode. The remote
control also stores the speed that was set in the previous
mode of operation.
Auto Mode: In AUTO mode, the unit automatically chooses
the fan speed and the mode of operation (COOL,DRY or
FAN). In this mode the fan speed and the temperature
are set automatically according to the room temperature
(tested by the temperature sensor which is incorporated in
the indoor unit.)
5. Timer Button: Use these buttons on the control panel
and remote to set the Timer.
Electronic Window
Air Conditioner
2
3
6
5
4
Timer Off: The timed stop is programmed by pressing the
TIMER button. Set the rest time by pressing the
buttons until the rest time is displayed to your preference
then press the TIMER button again.
Timer On: When the unit is off, press the TIMER button once
to set the temperature by pressing the
Press the TIMER button twice to set the rest time by pressing
the
or
buttons. Press the TIMER button three times
to confirm the setting, then the rest time will automatically
switch on and be read on the display of the machine.
Note: It can be set to automatically turn off or on in 0.5-
24 hours. The
buttons will increase or decrease the
timer. The Timer can be set in 0.5 hours increment below
10 hours and 1 hour increments for 10 hours or above.
The SET light will turn on while setting. To cancel the set
function, press the TIMER button again.
6. Eco Button: When the unit is in ECO mode, the light will
turn on. In ECO mode, the unit will turn-off once the room
is cooled to the user set temperature. The fan will also
be off at this point. The unit will restart when the room
temperature rises above the user set temperature. Before
the compressor starts, the fan motor will start and stop
repeatedly for cooling comfort and energy efficiency.
7. Sleep Button: Press the SLEEP button. The Sleep Light
will be on after, and all the remaining lights will be off. In
SLEEP mode, the air conditioner will automatically adjust
the temperature and fan speed to make the room more
comfortable during the evening. For cooling mode, the
set temperature will automatically raise by 1ºF or 2ºF
every 30-60 minutes and at most change six times until
the set temperature is 82ºF. For heating mode, the set
temperature will automatically decrease by 1ºF or 2ºF
every 30-60 minutes and at most change six times until
the set temperature is 75ºF. Every running time depends
on the set temperature.
8. Fan Speed Button: Press the FAN SPEED button to
choose the fan speed options. You can choose Hi, Med,
Lo or Auto speed in COOL mode and choose Hi, Med,
Lo in FAN mode.
9. Filter Button: When the Filter Check light is off, When
the Filter Check light is on, the light by pressing the
Filter Check button. After the fan motor works for 500
total hours, the Filter Check light will turn on to remind
the user to clean the filter. it isn't necessary to press the
Filter Check button. you can turn off.
10. Directional Louvres: To direct the airflow, use the
horizontal wheel to control the horizontal direction and
the air deflector to control the vertical direction.
Air Deflector
Fig. 5
4
User's Manual
or
Horizontal Wheel
Air Deflector
or
buttons.

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

292854

Tabla de contenido