DELIVERY, STORAGE, INSTALLATION

2.1 Delivery

Every system is factory-tested prior to delivery.
The system is despatched in packaging which offers the greatest possible protection and conforms
to the requirements of the haulage company.
Any damage is to be notified to the haulage company immediately upon receipt of the goods.
Katadyn accepts no costs for damage incurred during transport.
In the main, Katadyn systems are preassembled. Transport packaging will also include all non-
preassembled parts, some individually packed, in accordance with the scope of the supply.
All components are to be removed from their respective packaging with care.

2.2 Storage

All components are to be protected from moisture and cold whilst not in use. Both elements and
containers may burst if subject to frost.

2.3 Installation

Installation may only be carried out by authorised personnel.
All components are to be installed in such a way that the minimum clearances as specified in the
dimensional diagrams are adhered to.
Prior to installation, components are to be checked for dirt, and cleaned as necessary.
All components are to be handled with the greatest possible care, and are to be protected against
damage and contamination.
Important: The correct direction of flow must be observed!
2.4 Installation of Filters, Elements
The filter is to be fixed to the wall or floor using masonry screws (with wall plugs). The filter flange
should be positioned about 1.2 m above the floor (MF-7) to enable effortless cleaning. Filter types
MF-31/-54 should have a space of 1.8 m from base to ceiling allowing the lid to be opened widely
and the elements to be cleaned easily.
If a pressure booster unit is used, the filter must be installed after the pressure chamber.
If pressure surges occur in the water pipe, e.g. as a result of quick-action magnetic valves or
butterfly taps, etc., they are to be sufficiently reduced by using pressure surge dampers.
When the filter has been successfully installed, the filter elements are screwed in. All filter elements
must always be screwed in. Care must be taken to provide a rubber seal on every filter element
thread.
The filter elements are to be tightened thoroughly, but without force (2-3Nm)
~ 4 ~