Mechanical
Supply
Miscellaneous
Management Connectivity
Expansion LINK BUS (16x16 ch.)
Aux. Power Supply for Remotes & GPI
Time and date retention (battery)
SOFTWARE
Minimum EclerNet System Requirements
Dimensions (WxHxD)
Weight
Mains
Power consumption
Remote Bus
GPI
GPO
RTC accuracy
EclerNet Software
Operating System
482.6x44x266.5mm
3.5kg
90-264VCA 47-63Hz
45VA
Ethernet Base-Tx 10/100Mb Auto X-Over CAT5 up to
100m.
Proprietary over CAT5, Xover cable up to 100m.
2, over twisted pairs; up to 1km (see specific specs.)
8, from 0 to 10VDC or TTL level
8, 3 poles isolated relay; 1A, 48VDC max.
+12VDC, 1.2A. max. (short circuit protected)
1 month aprox. (ambient temperature dependant)
±1 minute /year
Realtime full GUI of all functions and controls
thru Ethernet with interactive graphical display
Grouping mode channels or devices
Grouping of other groups
Automated report generation
Up to 256 devices on same net
Autodiscovery devices feature
Routing capability through NAT gateways
Real time metering at input/output (DSP)
Device "Finder" feature
Save & Recall setup and preset functions
Firmware update capability thru Ethernet
Password protection (device & project with two user
levels)
Default Network configuration:
IP: 192.168.0.100
Mask: 255.255.255.0
Gate: 192.168.0.1
UDP Port: 2210
Windows® 10; W8.1; W8; W7; Vista (SP1); XP Prof.
(SP3); W2000 Prof. (SP4)
Pentium IV ® 1GHz
512MB RAM
40MB HDD free space
800x600 pixels & 16bits color display
10/100/1G Ethernet Network card
18