Troubleshooting
The following is a list of potentially occurring problems (P) and the possible causes.
15.1 Fresh water system
(P) N
O WATER COMES OUT OF THE TAPS
Leave the tap in the bathroom and kitchen open for a few seconds to allow air to escape, which may have
become trapped in the water lines.
→ The fresh water tank is empty.
→ The fresh water pump is not switched on. (The symbol on the control panel is off.)
→ The filter of the fresh water pump is clogged.
→ The drain valves are open.
→ The boiler is empty.
→ The fuse for the fresh water pump (F7) has blown. (The cause has to be determined.*)
(P) T
HE WATER DOES NOT DRAIN FROM THE KITCHEN SINK
→ The waste water tank is full.
→ The trap is blocked.
(P) W
ATER RUNS FROM UNDERNEATH THE VEHICLE
→ The fresh water tank is too full. Wait one minute until the excess water has drained.
→ The drain valve of the fresh water tank is open.
→ The waste water tank is full.
→ The drain valve of the waste water tank is open.
→ The drain valve of the boiler is open.
15.2 Electrical system
(P) O
NE OR SEVERAL ELECTRICAL APPLIANCES ARE NOT WORKING
→ The appliances are not in the "ON" position.
→ Circuit breaker B1 or B2 interrupts the current flow and has to be deactivated.
→ The power supply on the control panel is not activated.
→ The living room battery B2 is discharged. (See item 7.12 "Charging the living room battery B2".)
→ The 230 V power supply is not established. (See item 7.4 "Establishing the 230 V power supply".)
→ The RCD was triggered. (The cause has to be determined.*)
→ The fuse for the corresponding appliance has blown. (The cause has to be determined.*)
(P) T
HE INTERIOR LIGHTING IS NOT WORKING
→ The power supply on the control panel is not activated. (The symbol on the control panel does not
light up.)
→ The light unit is switched off or defective.*
→ The fuse for the interior lighting (F5 or F6) has blown. (The cause has to be determined.*)
(P) T
HE EXTERIOR LIGHTING IS NOT WORKING
→ The power supply on the control panel is not activated. (The symbol on the control panel does not
light up.)
→ The light unit is defective.*
→ The fuse for the exterior lighting (F8) has blown. (The cause has to be determined.*)
(P) T
230 V
HE
SOCKET IS NOT WORKING
→ The 230 V power supply is not established. (See item 7.4 "Establishing the 230 V power supply".)
→ The RCD was triggered. (The cause has to be determined.*)