SOCKET IS NOT WORKING
→ The control panel is not activated.
→ The living room battery B2 is discharged. (See item 7.12 "Charging the living room battery B2".)
→ The fuse for the 12 V socket (F9) has blown. (The cause has to be determined.*)
(P) T
HE ELECTRIC STEP IS NOT WORKING
→ The living room battery B2 is discharged. (See item 7.12 "Charging the living room battery B2".)
→ The fuse for the electric step (F4) has blown. (The cause has to be determined.*)
→ The step is defective.*
15.3 Heating
(P) T
HE HEATING IS NOT WORKING
→ The "heating" circuit breaker interrupts the current flow and has to be deactivated.
→ The heating control panel (Truma CP plus) is not switched on.
→ The fuel tank of the vehicle is empty.
→ The 230 V power supply is not established. (See item 7.4 "Establishing the 230 V power supply".)
→ The selected temperature is lower than the actual room temperature.
→ The intake opening for circulating air inside the vehicle is blocked.
→ The air intake/outlet element on the outside of the vehicle is blocked.
→ The window with the contactor on the window pane (if fitted) is not closed properly.
→ The fuse for the heating (slot 1) has blown. (The cause has to be determined.*)
15.4 Toilet
(P) T
HE TOILET SLIDE VALVE IS NOT WORKING
→ The cassette is full.
→ The cassette is not correctly engaged.
(P) T
HE TOILET CASSETTE CANNOT BE PULLED OUT OR PUSHED IN
→ The toilet slide valve is open or partially open.
(P) T
HE TOILET CANNOT BE FLUSHED
→ The fresh water tank is empty.
→ The fresh water pump is in no-load operation because there is air in the system.
→ The cassette is not correctly engaged.
→ The fuse for the toilet (F9) has blown. (The cause has to be determined.*)
15.5 Kitchen
(P) T
HE REFRIGERATOR IS NOT WORKING
→ The refrigerator is switched off.
→ The living room battery B2 is discharged. (See item 7.12 "Charging the living room battery B2".)
→ The fuse for the refrigerator (slot 2) has blown. (The cause has to be determined.*)
(P) T
HE HOB IS NOT WORKING
→ The safety valve on the gas cylinder (gas cylinder compartment) is closed.
→ The gas cylinder is empty.
(P) H
IGH GAS CONSUMPTION
→ The gas system has a leak.*
.
.
.
.
.
.
.
/
GAS ODOUR
Troubleshooting
.