Motor Protection Circuit Breaker
Voltage (V)
X1, X2 mm
inch
400
30
1-3/16
500
30
1-3/16
690
50
1-31/32
*
)
*
Minimum distance to grounded parts or walls
)
Minimaler Abstand gegen geerdete Teile oder Wände
Distance minimale envers pièces mises à terre ou parois
Distanza minimale per pezzi a massa o pareti
Distancia minima a chasis o paredes
Interrupting Ratings
Rated
Current
[A]
I
n
0.5
100
1.0
100
2.0
100
3.0
100
4.0
100
5.0
100
6.0
100
100
8.0
10
100
12
100
100
15
100
20
25
100
30
100
100
35
100
40
Publication 140UT-IN001A -MU-P - August 2021
Y mm
inch
9
23/64
9
23/64
30
1-3/16
Breaking Capacity (50 Hz)
[kA]
230...240V
400...415V
lcu
lcs
lcu
lcs
lcu
100
100
65
65
100
100
65
65
100
100
65
65
100
100
65
65
100
100
65
65
100
100
65
65
100
100
65
65
100
100
65
65
100
100
65
65
100
65
50
65
100
65
50
65
100
65
50
65
100
65
50
65
100
65
50
65
100
65
50
65
100
65
50
65
-WTEN
Wiring Diagrams for
3- or 2-Phase Application
Interrupting Rating (60 Hz)
525V
690V
240V
lcs
lcu
lcs
65
50
50
100
65
50
50
100
65
18
10
100
65
18
10
100
65
18
10
100
65
18
10
100
65
18
10
100
65
10
6
100
65
10
6
100
30
10
6
65
30
10
6
65
30
10
6
65
25
10
6
65
25
10
6
65
25
10
6
65
25
10
6
65
‡ Up to 12A suitable for continuous operation at 100% of rating only if used in a cubicle space of:
‡ From 15A up to 40A suitable for continuous operation only if used in a cubicle space of:
PN- 617951 DIR 10006010738 (Version 00)
Steps for
a proper
connection
1. Prepare wires according to the instructions
2. Open terminal screws completely
3. Insert wires fully in the correct position
4. Tighten terminal screws with the required torque
5. Check for solid connection by pulling on all the wires
[kA]
2 Pole
Cat. No.
480Y/277V 600Y/347V
100
50
140UT-D7D2-A50
100
50
140UT-D7D2-B10
100
50
140UT-D7D2-B20
140UT-D7D2-B20
100
50
140UT-D7D2-B30
100
50
140UT-D7D2-B40
100
50
140UT-D7D2-B50
100
50
140UT-D7D2-B60
100
50
140UT-D7D2-B80
100
50
140UT-D7D2-C10
65
25
140UT-D7D2-C12
65
25
140UT-D7D2-C15
65
25
140UT-D7D2-C20
65
25
140UT-D7D2-C25
65
25
140UT-D7D2-C30
65
-
140UT-D7D2-C35
65
-
140UT-D7D2-C40
480Y/277V - 250 x 175 x 150 mm (10 x 7 x 6 inch)
600Y/347V - 300 x 175 x150 mm (11.81 x 7 x 6 inch)
480Y/277V - 250 x 175 x 150 mm (10 x 7 x 6 inch)
600Y/347V - 300 x 175 x150 mm (11.81 x 7 x 6 inch)
Suitable for backfeeding at the ratings shown above.
3 Pole
Cat. No.
140UT-D7D3-A50
140UT-D7D3-B10
140UT-D7D3-B20
140UT-D7D3-B20
140UT-D7D3-B30
140UT-D7D3-B40
140UT-D7D3-B50
140UT-D7D3-B60
140UT-D7D3-B80
140UT-D7D3-C10
140UT-D7D3-C12
140UT-D7D3-C15
140UT-D7D3-C20
140UT-D7D3-C25
140UT-D7D3-C30
140UT-D7D3-C35
140UT-D7D3-C40

Publicidad

loading

Este manual también es adecuado para:

140ut-d7d3-a50140ut-d7d2-b10140ut-d7d3-b10140ut-d7d2-b20140ut-d7d3-b20140ut-d7d2-b30 ... Mostrar todo