MUTO PREMIUM SELF-CLOSING 120
—
Opening damper
CAREFULLY READ THE INSTRUCTIONS BEFORE USE
Regarding these instructions
These instructions are for the installation of
the opening damper of the MUTO Premium
Self-Closing 120 system.
Target group
Only properly qualified staff is authorized to
mount DORMA glass fittings.
Intended use
- for sliding doors in dry indoor areas only
Safety instructions
In order to ensure your safety please follow
the instructions in the installation manual
of your MUTO sliding door system. Read
these instructions before you begin with
the installation. An incorrect installation
can lead to serious injuries.
- Always wear protective clothing
Product description
When opening the door, the self-closing unit
is tensioned and therefore enabled. Where
the door may be subject to an undesired
opening force an optional damper unit can
be installed on the opening cycle without
compromising the hold open function.
TRANSLATION OF THE ORIGINAL MANUAL
KEEP IT FOR LATER CONSULTATION
Symbols used in this manual
1 2
Installation sequence
Individual steps within an
1
2
installation step
Closing edge
Maintenance, care, repair
- minimum of 5 years maintenance-free
operation (based on 50 cycles per day)
- immediately replace damaged parts
- always use original DORMA parts
Disposal
Dispose in accordance with national
regulations.
EN