Installation of the control unit
5.1
Connection of the TENSION
1
2
3
Connection of the MOTOR
5.2
Pay particular attention not to invert the OPEN and CLOSE
poles.
When in doubt as to the correct connection, if possible, ma-
nually position the automation at the midpoint of its stroke. Be
ready to stop the system using the STOP control!
To be sure that the opening is really "opening", try to block the
photocells: if the gate begins to close, the connection is incor-
rect and the motor OPEN and CLOSE wires must be inverted.
5.3
Connection of the LAMP
Here is the connection of a 230Vac lamp with or
without flashing card.
4
5
4
5
All manuals and user guides at all-guides.com
Connection to the
electric network
230 Vac
Phase
Neutral
with
flashing card
26
27
230 Volt Single-phase alternate cur-
rent. The control unit power supply
line must always be protected with
a magnetothermal switch or a pair
of 5A fuses.
A differential switch is recommended but not indi-
spensable if one is already installed on the plant.
4
• LAMP IN PAuSE TIME
To activate a function in the pause time,
see S05 as shown:
S 05
without
flashing card
-15-
Technical manual
5
7
8
9
6
MOTOR 1
MOTOR 2
LAMP IN PAUSE TIME
1 - Activated
0 - Deactivated
10
11