8
Reinstall the terminal block access cover.
White Wire from Dryer Harness
a
Hot Leads of Power Cord (Black and Red)
b
Neutral Wire (White)
c
External Ground Wire (if required by local
d
codes)
Ground Screw
e
Three-Wire Direct Wire
• A 3-wire connection is NOT
permitted on new construction after
January 1, 1996.
• A UL-listed strain relief is required.
• Use UL-listed 3-wire, #10 AWG minimum
copper conductor cable. Allow at least 5 ft. (1.5
m) length to allow for removal and installation
of dryer.
1
Remove 3.5 inches (8.9 cm) of the outer
covering from the wire. Strip 1 inch (2.5 cm)
insulation from each wire. Bend the ends of
the three wires into a hook shape.
2
Remove the terminal block access cover on
the upper back of the appliance.
3
Install UL-listed strain relief into the power
cord through-hole.
4
Thread the 3-wire, #10 AWG minimum copper
conductor power cable prepared in step 1
through the strain relief.
5
6
7
8
9
1'' (2.5 cm)
Connecting the Water Inlet
Hose
To generate steam, the dryer must be connected
to the cold water tap using a new water supply
hose. Do not use old hoses.
INSTALLATION
Terminal block
a
UL-listed strain relief
b
UL-listed 3-wire power cord
c
Attach the two hot leads (black and red) of the
power cord to the outer terminal block
screws.
Attach the neutral (white) wire to the center
terminal block screw.
Connect the external ground (if required by
local codes) to the green ground screw.
Tighten all screws securely.
Reinstall the terminal block access cover.
Hot lead (black and red)
a
Neutral wire (white)
b
External ground wire (if required by local
c
codes)
Wire from the appliance harness
d
Ground screw (green)
e