Descargar Imprimir esta página

MicroPower SMC-HF 600/800 Instrucciones De Uso página 11

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 43
The charging process must be switched off when disconnecting the battery. If the
battery is disconnected while the charging process is in progress, the contacts in
the charging connector will be damaged and sparks may be generated that could
cause a hydrogen explosion.
Sharp 32
6. Switching o
the battery charger.
7. The STANDBY LED comes on, showing a green light.
8. Disconnect the battery from the battery charger.
Maintenance
May only be carried out by authorised personnel.
Periodically, depending on location, the equipment should be checked and cleaned of
dust etc.
Troubleshooting
May only be carried out by authorised personnel.
Safety shut-off
Charging is interrupted if:
The recharged number of ampere-hours exceeds the estimated value.
The charging time for any of the charging phases exceeds the calculated value.
The voltage and current exceed the approved average value.
The battery has been disconnected without the charger being switched o .
Charging will be temporarily interrupted or reduced if:
The temperature exceeds the permitted values.
Check of error messages
Sharp 32
When the battery charger's built-in self-test detects a fault, this is indicated by the
fault in the charger.
WARNING
11