TO AVOID SERIOUS INJURY:
Do not exceed the maximum air pressure capacity of the Nailer. If the tool does not yet
have sufficient force at maximum pressure or sufficient air flow, then a higher capacity tool
may be required. Check with your regular seller.
When work is complete, disconnect the air supply, safely discharge all residual compressed
air from the Nailer, and release the trigger before performing any inspection, maintenance,
or cleaning procedures. Try firing the Nailer into a piece of scrap wood to make sure it is
disconnected and is not capable of firing any nails. Empty the drum and leave it open until
the next service.
Store the tool indoors, in a dry place and out of the reach of children.
Do not adjust or alter any control or component in a manner not expressly specified in this
manual. Improper adjustment can result in Nailer failure or other serious hazards.
TECHNICAL SPECIFICATIONS.
Net weight.
Working pressure range.
Maximun working pressure.
Air entrance.
Average air consumption.
Fixing elements.
Drum load capacity.
Noise.
L
PA = Acoustic pressure.
L
WA = Acoustic power.
L
PC = Maximun acoustic pressure..
K =
Data uncertainty.
Vibration.
MAINTENANCE.
This part of the manual is important for the correct use and care of the Nailer.
Daily: Maintain air supply according to manufacturer's instructions. Maintain the lubricating oil
level. Drain the moisture filter regularly. Performing an air supply maintenance routine will allow
the Nailer to work more safely and will also reduce wear.
Quarterly: disassemble, clean, and inspect the tool, keep the internal mechanism clean,
inspected, and lubricated by a qualified technician.
Lubricate the tool only with specific lubricants. Lubricate the air inlet using only pneumatic
tool oil. Lubricate the internal mechanism using only white lithium grease. Other lubricants
can damage the mechanism and can be highly flammable, causing an explosion.
It is recommended to avoid shocks and any form of exposure of the Nailer to falls, excessive
heat sources, or other situations.
1,2Kg.
4 – 7 bar.
7,5 bar.
¼" (6mm.)
40 L/min.
Nails (21Ga) 15-40mm.
100 pieces.
L
: 92,0 dB(A), K
WA
L
(in operator's position): 81,0 dB(A), K
PA
L
,(operator´s position peak): <130,0 dB, K
PC
ah:3,2 m/s2, K:1.4 m/s2
19
: 2.5dB;
WA
: 2.5 dB;
PA
:2.5 dB
PC

Publicidad