2 Product description
MENU → CONTROL
→ Mode:
→ DHW circuit 1
→ Mode:
→ DHW boost
→ Ventilation
→ Mode:
→ Air quality sensor 1:
ppm
→ Heat recovery:
→ Air quality limit: ppm
→ Ventilation boost
→ Humidity prevention
→ Time programme assistant
6
→ Manual
Uninterrupted retention of the domestic hot water temperature
→ Time-contr.
Domestic hot water weekly planner: Up to three time periods can be set per day
DHW temperature: °C: Applies within the time periods
Domestic hot water mode is switched off outside of the time periods
Circulation weekly planner: Up to three time periods can be set per day
The circulation pump pumps hot water to the draw-off points within the time periods
Outside of the time periods, the circulation pump is switched off
→ Off
Domestic hot water mode is switched off
→ Manual
Uninterrupted retention of the domestic hot water temperature
→ Time-contr.
Domestic hot water weekly planner: Up to three time periods can be set per day
DHW temperature: °C: Applies within the time periods
Domestic hot water mode is switched off outside of the time periods
→ Off
Domestic hot water mode is switched off
Heating up the water in the cylinder once
→ Normal
Uninterrupted ventilation at ventilation level: Normal
→ Time-contr.
Weekly planner: Up to 12 time periods can be set per day
Normal ventilation level:: Applies within the time periods
Reduced ventilation level:: Applies outside of the time periods
→ Reduced
Uninterrupted ventilation at ventilation level: Reduced
Measures the CO
content of the room air
2
→ On
Uninterrupted recovery of the heat from the extract air
→ Auto
Internal check of whether the outdoor air is guided via the heat recovery or directly into the living
room. See the operating instructions for the ventilation unit.
→ Off
Heat recovery is switched off
The ventilation unit keeps the CO
Heating mode is switched off for 30 minutes and, if available, the ventilation unit runs at the highest
ventilation level.
→ Max. room air humidity: %rel: If the value is exceeded, the dehumidifier switches on. If the value
is not reached, the dehumidifier switches off.
Programming of the desired temperature for Monday–Friday and Saturday–Sunday; the program-
ming applies for the time-controlled Heating Cooling, Domestic hot water, Circulation and Ventil-
ation functions
Overwrites the weekly planner for the Heating, Cooling, Domestic hot water, Circulation and
Ventilation functions
Operating and installation instructions sensoCOMFORT 0020287900_00
→ DHW temperature
→ Domestic hot water weekly planner
→ DHW temperature: °C
→ Circulation weekly planner
→ DHW temperature: °C
→ Domestic hot water weekly planner
→ DHW temperature: °C
→ Normal ventilation level:
→ Weekly planner
→ Normal ventilation level:
→ Reduced ventilation level:
content in the room air below the set value.
2