Descargar Imprimir esta página

Rechner Sensors IAS Serie Manual De Instrucciones página 13

Ocultar thumbs Ver también para IAS Serie:

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

Information on ETL certified sensors
ETL certified sensors of the series KAS-40/70/80...:
• Indoor use only
• For use in class 2 circuit only
• Uniquement pour utilisation dans circuits classe 2
3110580
ETL certified sensors of the series KAS-90/95...:
• Indoor use only
• Listed Component Conforms to UL Std. 61010-1
• Certified to Can/CSA Std. C22.2 No. 61010-1
• A fuse has to be installed directly at the AC supply (max. 250 V / 2 A, fast). A marked
emergency cut off switch must be installed for the user within easy reach of the unit.
General description
Typical application for capacitive sensors
Our capacitive sensors contain a transistor oscillator that oscillates as soon as a certain capacitance is
exceeded by the approach of the medium. The smaller the dielectric constant (Ɛ
has to be approached. Our KAS sensors (capacitive proximity switches / sensors) detect all media (in-
cluding liquids). The effect can also be achieved by detecting through non-metal materials (max. 4 mm),
if the dielectric permittivity of the material to be detected is higher (approx. factor 5). Depending on the
version, the current change of the oscillator is amplified into an analogue output signal or output as a
binary signal via a switching amplifier.
• Output stages with npn or pnp transistors are available for DC operation.
• A transistor output stage or FET-output is integrated for AC connection.
Detection of all materials directly
in a container
(non-flush version)
(= Symbol for protection class 2)
Detection of all materials through
a nonmetallic container or an
inspection window (flush version)
), the closer the medium
r
13

Publicidad

loading

Este manual también es adecuado para:

Kas serie