954251.book : I95425us.fm Seite 4 Montag, November 23, 1998 10:28 AM
Maintenance and Care
E
Maintenance
For Maintenance, see figs. [10], [11] and fold-out
page II.
D
Shut off cold and hot water supply.
W
I. Ceramic cartridge, see fold-out page II.
X
Unscrew the ceramic cartridge (3, 4) using a 17 mm
(11/16") wrench.
II.Vacuum breaker, see fig. [10] and fold-out
page II.
[10]
Pull off cover (E) and tube (D), see fig. [10].
Remove circlip (W), pull out and replace double-ball
vacuum breaker (X).
Loosen nut and replace check valve (15.4), see fold-
V
out page II.
III.Vertical spray, see fig. [11].
Screw off spray face plate (V) and nozzle (T).
T
Check, clean and if necessary replace parts.
Grease with special valve grease (Cat.No. 18 012).
Assemble in reverse order.
[11]
Only original Grohe replacement parts may
be used.
Care
Instructions for care of this bidet wideset will be
found in the Limited Warranty supplement.
English
4