10. FACTORY SELF-CALIBRATION
If the customer self-calibration will not be helping
to maintain the machine to have satisfactory ba-
lancing stability, we recommend that you proceed
Factory Self-Calibration procedure.
Below you would find the detailed instruction:
Press "Home button" one time
,and it
displays "[ P ]", press "DIS + button" one time
, and you will see "[ SET ] - [ UP ]"
Press "Home button" two times
, and it
dispalys [POS—XXX], pull the wheel by hand
(clock-wise or anti-clock-wise) slowly.
When it displays [ POS ]—[ 110 ] press 'Fine
button" one time
, then continue to pull
the wheel slowly until it displays [ POS ]—[ 120
] Press " Fine button" one time
.
The screen displays [ ADD ]-[ 0 ], press
to start rotation of the machine.
When machine stops rotation, it displays [ ADD
]—[ 100 ], at this moment, please pull the wheel
until the outer indicating lights are all illuminating,
clamp 100g calibration standard weight on the
outside rim at 12 o'clock position. Press
to start rotation of the machine .
When the machine stops, it displays "100—ADD":
at this moment please remove that 100g standard
weight from the outside rim edge firstly, then pull
the wheel by hand until the inner indicating lights
are all illuminating, clamp that 100g standard
weight on the inside rim at 12 o'clock position,.
Press
to start the rotation again.
When it stops, you will hear 3 times beeps indi-
cation and the Factory Self-Calibration is over.