If you can not solute by the above mentioned method, pls contact with the professional persons.
7.2 ERROR INDICATION
DISPLAY
CAUSE
ERR
Protective cover
OPN
not lower down
ERR
Rotation speed
SP
not enough
Photocell coupler
cannot collect si-
gnal
Error of stop
ERR
OFF
ERR
Factory set-up
FAC
fault
ERR
Customer set-up
USR
fault
Reverse rotates is
not correct
ERR
REU
If cannot solve as per the above methods, please
contact the professional personnel.
48
SOLUTION
Lower down the
protective cover.
Check the motor
and belt.
Lower down the
protective cover
Press the start
key or rise up the
protective cover.
Correct factory
set-up
Customer set-up
Troubleshooting of
power board.
Check power cable
connection correct
or not, the wire
sequence of the
3-phase motor
must be correct.
7.3 PRESS SENSOR
INSTALLATION AND WIRING
Sometime, the troublesome of inaccuracy of
balancing and position if because the damage
of the press sensor. The method to change the
press sensor is shown in the following:
- Demount the upper cover and right side panel
of the wheel balancer.
- Remove the nut 1&2, elastic washer, sanding
washer and plain washer.
- Loose the nut 3, 4 and 5 to disassemble each part.
- Change the new sensor and mount the double
head screw and tight the nut 5.
- Use the spanner to tight nut 4 slightly and then
tight nut3. At this time, pay attention that the
horizontal and vertical sensor screw should to
ProLine 60 - Operator's Manual