INSTALLATION MANUAL
DECORATIVE ELECTRIC PUMPS
1. SAFETY STANDARDS
ENG
MICRA, MICRA PLUS, NOVA, IDRA, EXTREME
Before carrying out any work on the pump, disconnect all electrical equipment immersed in wa-
ter from the power supply. This pump is for indoor use only. It must not be installed if the pump
or the cable is damag o the mains voltage. THE PUMP MUST NOT OPERATE DRY AND CAN BE
USED IN LIQUIDS WITH TEMPERATURE NOT ABOVE 35 o C!
2. USE
For correct operation, a minimum water height of about 2 cm is recommended. Ø 12x16 hoses
can be connected to the pump, using the adaptor supplied, as well as Ø 13 mm rigid pipes (fig.
2). The water flow rate can be modified by means of the flow regulator, which allows precise
and easy dosing according to requirements (fig. 1).
3. MAINTENANCE
MICRA is a centrifugal pump with magnetic drive, driven by a synchronous motor with water-
tight seal. It requires minimum but important maintenance for proper operation. The pump is
equipped with a small filter (fig. 3) which must be cleaned at regular intervals, or if the water
flow decreases excessively.
To do this, simply remove the front part (fig. 3) and rinse the filter material.
Remove in reverse order.
The other parts should be washed every 3 months with lukewarm water, gently removing any
limescale deposits.
www.proindecsa.com / proindecsa@proindecsa.com
8