TROUBLESHOOTING
Problem
The unit does not
turn on
Cooling
chamber
temperature
high
Cooling
chamber
temperature too low
The unit generates
vibrations
Occurrence
moisture inside the
unit chamber
Possible cause
No proper connection of the
unit
Power switch off
No current in the power
socket
The fuse is damaged
Incorrectly defined cooling
too
temperature
Too
high
opening the unit door or
leaving the door ajar for a
long time
Unit door not closed
Failure in power supply of
the unit
Incorrectly defined cooling
temperature
Failure to level the unit
properly
Incorrect distance between
the rear panel of the unit
and the wall / object behind
it
of
Too high frequency of
opening the unit door or
leaving the door ajar for a
long time
Lack of proper door closing
frequency
of
x
Action
Check
the
connection of the unit
Turn on the unit with the
power switch
Check voltage at power
socket
Contact the manufacturer's
service department.
Perform chilling temperature
configuration
Check frequency and time of
door opening
Check that the door is tight /
closed properly
Reconnect the unit and wait a
minimum of 4 hours for the
cooling
temperature
stabilize
Perform chilling temperature
configuration
Re-level the unit
Use
the
required
distance of 30 cm
Restart the unit. If the
problem persists, contact the
manufacturer's
department
Check frequency and time of
door opening
Check that the door is tight /
closed properly
correct
to
safe
service