TROUBLE-SHOOTING
Error codes
Error code
"Acoustic signal upon
ignition.
No error code
displayed"
ER03
ER20
ER21
ER22
ER31
ER36
ER47
E2
E3
E4
50
Description
The hood command does
not work
Continuous sensor
activation. TC turns off
after 10 sec.
TC internal error
Overheating.
Faulty button assessment.
The user interface switches
off after 3.5 - 7.5 seconds.
There is an inconsistency
in the configuration of TC
and induction.
TC internal error
Communication error
between TC and induction
Cooking area sensor
overheats. TC turns off
after 10 sec.
Wrong pan.
The cooking areas are Off.
Configuration error. The
cooking area cannot be
activated.
Possible cause of the
error
LIN cable damaged or badly
connected to the hood
electronic board
Water or pan on glass, on
sensors or on control.
-
The temperature control has
detected a temperature higher
than 85°C.
-
The generator configuration
data do not coincide with those
of the TC.
-
LIN cable damaged.
There is no power supply in the
LIN cable.
Pan empty
The pans are losing their
magnetic characteristics
Internal error in generator
circuits
The induction module is not
configured yet.
Solution
check connection/replace the
LIN cable
Clean the surface of the
control. Remove the objects
from the sensors.
Replace TC.
Leave the hob to cool down
and the error will disappear
when the temperature is
below 75°C.
Check the thermal insulation.
Replace TC
New configuration.
Replace TC.
Change the generator.
Replace TC.
Replace the Cable.
Check that the Cable has
been inserted properly.
Do not heat empty pans.
Use appropriate pans
Replace the module
Perform manual configuration.