5) ADDRESSING
The 2-Wire system allows installing up to 3 outdoor stations at the same time, regardless of their type (excluding art. VI-PEAUX). The outdoor stations must be addressed by means of the dip switch (3)
located at the rear of the devices (figure 3).
6) SETTING THE UNLOCKING TIME OF THE ELECTRIC LOCKS
The devices are equipped with a trimmer (2) to adjust the closing time of the unlocking relay with change-over contact (min 1 s – max 10 s). To increase the closing time of the relays, turn the trimmer
clockwise.
7) DOOR OPEN SENSOR INPUT (GS)
The "Door open" status can be monitored by connecting a normally open sensor (e.g. AF902, AF903, etc...) to the GND and GS terminals. The "Door open" status detection is automatically enabled when
the GS input remains closed for more than 30 s; then, if the input is left open for more than 2 min., the outdoor station emits an acoustic signal until the input is closed again. The indoor stations emit
an optical signal (depending on the model) to warn of the "Door open" alarm.
8) DOOR OPENING BUTTON INPUT (DOOR)
A normally open button (e.g. 441005) can be connected between the "DOOR" input and the GND terminal: a short pressure acts on the output of the powered relay (EL).
9) ANALOGUE CAMERA INPUT
It is possible to connect an analogue camera directly to the connector; the camera will be displayed on indoor stations in sequence to the main camera of the device.
10) PROGRAMMING OF CARDS
A MIFARE® card reader, which can be managed using the 44339CHU-MB card, is integrated in the VI2F-PE7T outdoor station. The card programming procedure can be found in the complete manual
of the 2-wire system available on the website www.ave.it
11) TYPE OF CALL
The device allows two different types of calls: from a numeric keypad and from a user list.
11.1) Call from numeric keypad: enter the number of the apartment to which you want to forward the call and press the green call button.
If the apartment number is unknown, you can press the "Users" button and select the desired user directly from the list in the device. In case the number of users is high, you can scroll
through the various pages by pressing the scroll arrows. It is also possible to search by name: tap on the search box, enter the required name and press the "Magnifier" button on the keyboard.
11.2) Call from User list: press the user to whom you want to forward the call. In systems with a large number of users it is possible to consult the various pages through the scroll arrows.
11.3) Call to the concierge: if the system features a concierge, press the green "Concierge" button to forward the call to the concierge service.
12) UNLOCKING ELECTRIC LOCKS
On board the device there are two relays for the management of two gates. Relay contacts may be unlocked in five different ways:
12.1) Hold a MIFARE
card (Art. 44339CHU-MB) associated with the system
®
12.2) By means of a normally opened button connected to the appropriate "DOOR" input of the device
12.3) By entering the "Common Password": if the function has been activated in the appropriate menu, press the # button, enter the password and press # again to open the door
12.4) By entering the "User Password": if the function has been activated in the appropriate menu, press the * and # buttons, enter the User password and press # again to open the door
12.5) By pressing the appropriate release button on the outdoor station;
Note¹ The first four functions are reserved only to the first relay (with powered outlet).
Note² When the device leaves the factory, the "Common Password" parameter is disabled. The default "Common Password" is 666666.
Note³ The "User password" can only be entered by means of the appropriate PC software and the VI2F-PROG interface.
13) ACCESS TO THE CONFIGURATION MENU
The configuration menu may be accessed in three different ways (password-protected access):
13.1) Numeric keypad: press the # and * buttons sequentially: the password entry field will appear. Enter the password 222222.
13.2) User List: remove the device from the wall and disconnect the power. Reconnect the power supply and move the rear dip-switches to 00 within one minute. Once the configuration has been
completed, return the dip-switches to the previous position.
The configuration menu can also be accessed by holding the administrator card close to the tag reader of the device.
13.3) Administrator Card: hold the card close to the tag reader. To create an Administrator card, refer to the complete manual of the device (see QR code at the bottom of the manual).
14) BASIC CONFIGURATION MENU
From this menu, it is possible to enter/edit the typical configurations of the User Interface.
14.1) Ringtones: from this menu, it is possible to change the settings related to the various tones of the device:
• Standby tone volume: adjust the volume of the forwarded call sound;
• Feedback tone: enab le the sound emitted by the device when a call is forwarded;
• Key tone: activation of acoustic feedback of the keys of the device;
14.2) Language: select the language of the device and press the OK button;
14.3) Password: activation of the various system passwords:
• Open with User Password: enable relay 1 unlock using "User Password";
• Open with Common Password: enable relay 1 unlock using the "Common Password" of the system;
• Change Common Password: allows editing the "Common Password" of the system;
14.4) Card Management: MIFARE
• Add a new card: approach a new card to be enabled for access management;
• Card list: display of the list (User + card number) of all the cards active on the system;
• Delete single card: select the number of the card to be deleted from the register and press OK;
• Clear card register: to delete all cards associated with the system.
14.5) Display: device display management menu:
• Brightness: to increase and decrease the brightness of the screen of the device;
• Activate Screensaver: to activate the screensaver function on the device;
• Screensaver ON after (s): to activate the time after which the screensaver is activated;
• LCD shut-down after (m): to activate the time after which the device display is turned off; simply tap the display of your device to reactivate it.
14.6) User List: menu to manage the names of the Users displayed by the device:
• Add user: to associate a new User to an apartment;
• Change user name: to change the name of an already registered user;
• Delete single user: to display the complete User list; from this menu it is possible to delete a single user;
• Clear user list: to delete the entire list of Users associated with the device.
15) ADVANCED CONFIGURATION MENU
From this menu it is possible enter /edit the typical configurations of the system.
15.1) Type of push-button panel: from this menu it is possible to change the type of page displayed by the display of the device:
• Keyboard: keyboard call mode;
• User List: user list view mode: Single-column or Double-column push-button panel. From this menu it is also possible to enable the call to the concierge indoor station (address 200);
15.2) Factory test: this is the menu from which audio and display tests can be carried out.
• Audio: the device emits sounds to test the audio of the device;
• Display: some images are shown to test the display of the device;
• Restart the System: press the button to restart the device;
• Restore the factory parameters: press the button to restore the factory parameters;
15.3) Configure password: menu from which it is possible to change the access password to the "Configuration menu" of the device;
15.4) Information: provides information on the device.
16) TECHNICAL CHARACTERISTICS
Operating voltage
Maximum operating voltage
Absorption during operation
Absorption during stand-by
Dimensions (L x H x D)
Weight
Protrusion from the wall
Environmental class as per EN 62820-1-1
Operating temperature
TO DOWNLOAD THE COMPLETE MANUAL OF THE 2-WIRE SYSTEM, SCAN THE QR CODE SHOWN ON THE DRAWINGS PAGE
®
card management menu:
24V
DC
32V
DC
400 mA max @ 30 V
DC
90 mA max @ 30 V
DC
148.5 x 369 x 49 mm
1.5 kg
9 mm
CLASS IV
From -25 °C to +55 °C
close to the tag reader of the device;
(1)
;
(1)
Maximum number of devices that can be installed
Camera
Installation
Protection rating
Door opening actuator #1
Door opening actuator #2
Maximum number of cards that can be managed
Maximum system length
Maximum altitude
;
(1)(2)
3
CMOS with white light illuminator
Wall or flush installation
IP20 (IP44 when installed)
Max 12V 13W
Monostable change-over relay
2000
200 m
2000 m a.s.l.
;
(1)(3)