NOTE: If the outdoor sensor is not used with H6062, as the outside temperature drops, a lower humidity set-
ting is recommended to accommodate dewpoint effects. These settings should reduce the accumula-
tion of moisture and ice on windows and other areas of the home.
• Adjust the humidity control setting to adjust for indoor activities such as cooking, showering and clothes
drying, which can cause excessive levels of humidity that can accumulate moisture on your windows.
NOTE: If these activities persist for more than a few hours, set the humidity control to the lowest setting to turn
off the humidifier. If the condition does not improve, ventilate your home to remove the moisture.
Table 2. Setting Your Humidistat when outdoor sensor is not used.
-20 °F (-29 °C)
-10 °F (-23 °C)
0 °F (-18 °C)
+10 °F (-12 °C)
+20 °F (-7 °C)
Above 20 °F (-7 °C)
MAINTAINING YOUR HUMIDIFIER
A regular maintenance program prolongs the life of your humidifier and makes your home more comfortable.
The frequency of cleaning depends on the condition of your water.
You can use either hard or soft water in your humidifier, but hard water mineral deposits are more difficult to
clean than soft water deposits.
Use the following procedure to clean your humidifier.
IMPORTANT
Never oil any part of the humidifier.
Once per year, depending on water quality
(either at the beginning or the end of the humidification season)
1. Disconnect the power by unplugging the transformer from the outlet and turn off the humidifier's water
supply at the shut off valve.
2. Remove the humidifier cover. See Fig. 20 on page 14.
3. Remove the humidifier pad assembly from the humidifier by grasping the top of the tray and pulling it
toward you.
4. Pull one side of the humidifier pad assembly frame toward you and remove the tray from the frame.
5. Gently pinch the water nozzle prongs (a pair of prongs is located on each side of the PerfectFLO
distribution tray) inward until you can lift the water nozzle off the tray.
6. Slide the humidifier pad out of the frame and discard the pad. It is recommended to replace the humidifier
pad on an annual basis. However, if your home has hard water, the pad may need to be replaced more
frequently.
7. Carefully remove any mineral deposits from the tray and frame. Be sure the frame drain hole has nothing
blocking it.
8. Disconnect the drain hose from the drain fitting on the bottom of the humidifier housing.
9. Clean the drain fitting, if necessary.
10. Bend the drain hose to loosen any mineral deposits.
11. Flush the drain hose with pressurized water (a running tap) to clean the hose.
12. Reattach the drain hose to the drain fitting.
13. Slide a new humidifier pad back into the frame.
14. Snap the water nozzle back on the tray.
15. Reattach the tray to the frame.
16. Place the humidifier pad assembly in the humidifier housing and press until the assembly is completely
seated. Be careful not to pinch or kink the water feed tube.
17. Replace the humidifier cover.
18. Verify the humidifier operation by following the steps in the Checking Your Humidifier for Correct
Operation section.
When Outside Temperature is:
Use This Control Setting:
15
20
25
30
35
40
13
HE240, HE280 HUMIDIFIER