Alarm
E00
Safety thermostat tripped
Electronic circuit board diagnostics
E05
Electronic circuit board diagnostics
E06
Electronic circuit board diagnostics
E07
Electronic circuit board diagnostics
E16
Electrical component compartment
E17
Electronic circuit board diagnostics
E20
E21
Control panel overtemperature
E22
Basket lifting failure
The water level in the cooking well
has dropped below the minimum
H2O
level, so the appliance is not heating
Causes
tripped.
tripped.
tripped.
tripped.
has overheated.
tripped
up.
- 17 -
Remedies
Carry out the appliance reset (see page 13)
Important
Inform the after-sales service
The appliance's functions are disabled so no
cooking cycles can be carried out.
Important
Inform the after-sales service
The appliance's functions are disabled so no
cooking cycles can be carried out.
Important
Inform the after-sales service
The appliance's functions are disabled so no
cooking cycles can be carried out.
Important
Inform the after-sales service
The appliance's functions are disabled so no
cooking cycles can be carried out.
Important
Inform the after-sales service
The appliance solves the problem on its own.
The appliance's functions are enabled and so
cooking cycles can be carried out.
The appliance's functions are disabled so no
cooking cycles can be carried out.
Important
Inform the after-sales service
The appliance solves the problem on its own.
The appliance's functions are enabled and so
cooking cycles can be carried out
The appliance's functions are enabled and so
cooking cycles can be carried out.
Inform the after-sales service.
Important
Inform the after-sales service
Top up the water level in the cooking well.
IT
GB
.
DE
FR
ES
English