WARNING: Never place tools or other ob-
ject into the fan.
WARNING: Never touch electrical compo-
nents with wet or damp hands.
WARNING: To ensure the cooling unit
works properly and at full capacity, make sure
air supply to the unit is not obstructed.
WARNING: Water temperature during sani-
tation must not be higher than 25 °C!
WARNING: Always make sure the power
socket you intend to plug the cooler into is ac-
cessible, so that the appliance can be immedi-
ately unplugged in case of emergency.
WARNING: When unplugging the device
from the socket, grab the plug and pull it out.
Do not under any circumstances pull at the ca-
ble; risk of damage.
WARNING: To turn the device off complete-
ly, unplug the appliance from the power sock-
et.
WARNING: In the event the electrical wiring
of the product becomes damaged, summon a
trained service technician. Do not under any
circumstances repair the device yourself.
WARNING: The cooling system contains
flammable coolant R290 (propane)!
WARNING: Emergency maintenance and
repair of the cooling system must be done by
trained, authorised technicians familiar with
cooling and electrical systems. The technicians
should have special training and qualification
for handling flammable substances in order to
perform service on coolers containing R290.
Follow basic regulations and safety measures
regarding service and repair!
WARNING: Do not use open flame or po-
tential sources of sparks in the vicinity of a
cooler using R290 coolant!
WARNING: After unpacking, place the cool-
er so that heat created by the cooling unit can
be vented sufficiently.
WARNING: Do not place objects that could
prevent air circulation on top of the cooler.
5. INSTALLATION AND PLACEMENT
Place the cooler onto a stable, level surface
(maximum permitted inclination: 2 degrees).
The appliance requires unobstructed air circu-
lation.
• Ensure sufficient free space for air circulation
and heat dissipation.
• Ensure sufficient supply of fresh air.
• The device must not be placed in an enclosed
space.
• The device must not be placed in the vicinity
of heat sources or exposed to direct sunlight.
Minimum distance of vents from an obstacle
that would limit air circulation must be 30 cm.
Minimum distance for sections with no air
vents is 7 cm. Ideally, use the device in a cool
and well-ventilated room. The device is de-
signed for use at ambient temperature of at
least 16 °C and at most 32 °C.
WARNING: The device MUST NOT be used
or stored at ambient temperature lower than
0 °C. The device is designed for use in a normal
environment, always under a roof, protected
from rain or sunlight. Climate class N.
DANGER: Protect the cooler and electrical
connection from rain and spraying water!
WARNING: Do not under any circumstanc-
es lay the cooler on its side, not even during
transport.
NOTE: In order for the device to work
correctly and at maximum output, it is im-
portant to not cover up any of the device's
vents and ensure sufficient air circulation.