Signal converter for screw-in flow controllers
BAE SA-FF-055-RS
Troubleshooting
Error
Possible cause
No LED
Incorrect or no
comes on.
supply voltage
Flow rate
Sensor operated
changes are
outside of
not indicated.
specifications or
incorrectly installed
Inverted
Wiring error on
response of
terminals 2 and 4
the LED
indicator(s)
Switching
Dirty/contaminated
response
sensor
changes
4
english
Technical data
Remedy
General data
Check supply
Display
LED green (4×)
voltage.
LED yellow
Check conditions
LED red
and installation
Operating panel
and correct as
needed.
Use
Check wiring and
correct as
Electric data
necessary.
Operating voltage
Switching voltage
Clean sensor.
Switching current
Current drain
Electrical Connection
Connector
Output / interface
Switching output
Materials
Housing material
Detection range / measuring range
Detection range
Ambient conditions
Storage temperature
IP rating per IEC 60529
Screw terminal IP rating
Ambient temperature
Limit exceeded
Limit reached
Limit undershot
Potentiometer screw
for screw-in flow controllers
20...28 V DC (SELV)
≤ 230 V AC / 30 V DC
1 A
≤ 70 mA
Screw terminals
Relay normally open (NO)
Plastic
Depends on flow sensor
–20...+60 °C
IP40
IP20
–20...+60 °C