Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 37
NOTE
Ensure that the outer surfaces of the gearing section
neck where the side handle is fitted are free from
oil and grease. If parts of the TE DRS BK/ E dust
removal module are oily and/or greasy when fitted,
the TE DRS BK/ E dust removal module and side
handle may rotate out of position while the power
tool is in use. Accordingly, take care to ensure that
the suction unit at the side handle clamping band is
not oily or greasy. Only parts that are free of grease
guarantee adequate friction between the side handle
and the power tool. Use a cleaning cloth to remove any
oil or grease from the outer surfaces of the gearing
section neck where the side handle is attached.
CAUTION
Only the pointed chisels, flat chisels, bushing tools
and percussion core bits shown in the illustration
may be used.
Remove any drill bit or chisel from the power tool
before attaching the dust removal module.
1.
Disconnect the mains plug from the power outlet.
2.
Turn the side handle counterclockwise to release
it from the power tool.
3.
Remove the side handle from the power tool.
4.
Select the correct dust removal system compon-
ents in accordance with fig. 4 and fit the parts to
the suction unit.

6. Operation

CAUTION
Observe the operating instructions for the Hilti
power tool used. Use the dust removal module
only in conjunction with the power tools listed in
fig. 2. Failure to observe this point presents a risk
of injury.
Printed: 07.07.2013 | Doc-Nr: PUB / 5071246 / 000 / 00
5.
Slide the assembled system, complete with the
side handle, over the chuck and onto the neck
of the gearing section, i.e. to the side handle
position.
6.
Rotate the suction unit and side handle into the
desired position.
7.
Secure the side handle by tightening the grip so
that it cannot rotate out of position.
8.
Before using the drill bit or chisel, grease the
connection end with the Hilti grease specified for
this purpose. Insert the drill bit or chisel in the
chuck. Please refer to the operating instructions
for the power tool for instructions on how to fit
the drill bit or chisel.
9.
Connect the vacuum cleaner to the dust removal
module.
5.2 Detaching the dust removal module 3
CAUTION
Wear protective gloves when changing insert tools
as the insert tools get hot during use.
1.
Disconnect the mains plug from the power outlet.
2.
Disconnect the vacuum cleaner from the dust
removal module.
3.
Remove the drill bit or chisel from the chuck.
4.
Release the side handle by turning the grip.
5.
Pull the complete dust removal module away
from the power tool.
6.
Fit the side handle to the power tool.
CAUTION
Take care to ensure that the module does not
overheat. The material from which it is made will
melt at a temperature of over 80°C.
CAUTION
Do not hold the power tool by the suction head or
suction hose while in use.
en
13

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Te drs-bk-e

Tabla de contenido