ABOUT CHEMICAL WATER TREATMENT
The- automatic- water- treatment- kit- makes- it- possible- to- monitor- and- control- fundamental- parameters-
without-any-intervention-by-the-user.-The-pH-value-is-regulated-by-introducing-small-doses-of-dilute-acid-
solution;-disinfection-is-guaranteed-by-the-constant-presence-of-an-optimum-amount-of-active-chlorine.
Before-starting-the-system,-it-is-recommended-always-to-carry-out-a-HYPERCHLORINATION-process;-
this-process-is-achieved-by-adding-an-amount-of-active-chlorine-(2-ppm)-directly-into-the-water.
Once-this-operation-is-complete,-the-system-will-generate-and-automatically-maintain-the-required-chlorine-
level-in-the-water.
HYPERCHLORINATION:
MANUAL METHOD
To- perform- the- hyperchlorination- process,- after-
24- hours- of- recycle- operation- to- keep- the- salt-
completely-dissolved,-use-the-control-panel-to-set-
the-"MAN"-mode.
Bearing- in- mind- that- with- activity- at- 100%,-
the- system- produces- 4- g/h- of- active- chlorine,-
therefore,-to-obtain-2-ppm-active-chlorine-in-2m
water:
2mg-
chlorine
2ppm-=
1000g-water
The system needs to be operated in manual
mode for approximately 1 hour.
After-this-time,-the-system-needs-to-be-operated-
in- "AUTO"- mode- for- the- entire- period- of- normal-
use.
After-the-hyperchlorination-process,-it-is-advisable-
to-wait-12-24-h-before-allowing-bathers-to-use-the-
water;-this-is-to-allow-the-chlorine-level-to-fall.
(The- waiting- period- depends- on- the- location- of-
the- pool.- Remember- that,- in- the- sunshine,- the-
effect-of-the-UV-rays-causes-chlorine-levels-to-fall-
more-quickly).
The- "MAN"- mode- can- be- set- each- time- that- a-
continuous,-notable-production-of-active-chlorine-
is-required-in-the-pool.
WATER-TREATMENT-KIT
-
3
2g-
chlorine
=
=
1m
-water
3
pH
Electrolysis
7.0 ... 7.8 pH
Control Mode
Setpoint
AUTO
SET
MAN
CAL
STOP
pH CONTROLLER
ON
ALARM
4g
chlorine
2m
water
3
pH
Electrolysis
7.0 ... 7.8 pH
Setpoint
Control Mode
AUTO
SET
MAN
CAL
STOP
pH CONTROLLER
ON
ALARM
EN
ORP mV
650...800 mV
Setpoint
SET
CAL
ORP CONTROLLER
ORP mV
650...800 mV
Setpoint
SET
CAL
ORP CONTROLLER
15