CALIBRATING THE pH DETECTION ELECTRODES
At-regular-intervals-of-no-more-than-one-month,-compare-the-pH-value-of-the-water-in-the-pool-with-that-
detected-by-the-automatic-treatment-system,-using-the-kit-supplied.
If-the-pH-values-differ-by-more-than-0.3-–-0.4,-then-the-pH-detection-electrode-will-need-to-be-readjusted.
Contact your nearest Authorised Technical Assistance Centre (see list attached).
CALIBRATING THE ORP (Chlorine) DETECTION ELECTRODE
At-regular-intervals-of-no-more-than-one-month,-check-the-value-for-the-chlorine-in-the-water.
In-the-event-of-excess-or-insufficient-chlorine,-increase-or-reduce-the-ORP-value-as-required-within-the-
range-permitted-by-the-device.
If-in-this-case,-too,-the-amount-of-chlorine-is-not-regular,-it-may-be-necessary-to-adjust-the-ORP-probe.
Contact your nearest Authorised Technical Assistance Centre (see list attached).
PLACING OUT OF SERVICE
FOR THE WINTER
Disenable- chlorine- production- by- pressing- the-
"Stop"-key.
1.-Disconnect-the-circuit-using-the-two-valves-and-
remove- the- probes,- keeping- them- damp- at- the-
ends-(For-long-periods).
Contact- your- nearest- Authorised- Technical-
Assistance- Centre- (see- list- attached)- to- perform-
this-operation.
2.-Keep-the-circuit-where-the-probes-are-housed-
flooded- (for- brief- periods)- by- turning- off- the- two-
circuit- shut-off- valves;- alternatively,- remove- the-
probes-and-place-them-in-their-original-packaging,-
taking-care-to-keep-them-wet-at-all-times.
Before using the water treatment kit again after
it has been left idle for the winter, proceed as
described for starting the system for the first
time.
WATER-TREATMENT-KIT
pH
Electrolysis
ORP mV
7.0 ... 7.8 pH
Setpoint
Control Mode
Setpoint
AUTO
SET
MAN
CAL
STOP
pH CONTROLLER
ORP CONTROLLER
ON
ALARM
EN
650...800 mV
SET
CAL