safety devices, high pressure hoses, trigger gun.
WARNING: Be aware of the recoil caused by the water jet when the machine is switched
on.
WARNING: When the machine is moving and installing, the machine must be in flat.
When moving the machine, pulling the handle to move it.
WARNING: Connect to the water supply. The machines are not suitable for connection
to portable water mains. Connect the machine to the water supply. (It can be a water
container).
Make sure the inlet water pressure keeps between 0.01MPa and 0.4MPa.The inlet pipe
should at least 5 M long. Do not use the pipe if the pipe is damaged. If you want connect
this machine to portable water mains, you must install a backflow preventer in the water
pipe to prevent dirty water flow back to the drinking water system. The backflow
preventer shall comply with EN 60335-2-79 ANNEX AA.
!
This unit is to be connected to a cold water source ONLY.
!
The motor of this pressure washer will NOT run. It will only operate when the trigger is
squeezed.
- Connect the outlet hose to the washer and connect the spray gun to the outlet hose.
- Connect nozzle and nozzle extension.
- Check gauze filter is clear of any blockage.
- Connect the water supply hose.
- Check that the hose has no kinks in it.
- Turn on water and check for leaks.
- Depress trigger to allow air to be expelled though the pump and hoses, lock trigger.
- Plug in machine and turn on switch.
- Unlock trigger and use the pressure washer.
1.
Turn off the motor(push switch to the off position).
2.
Unplug the unit from the power source.
3.
Turn off the water supply.
4.
Press the trigger of the gun to depressurize the system.
5.
Disconnect the garden hose from the pressure washer.
6.
Wipe all surfaces of the unit with a damp clean cloth.
7.
Engage the gun safety lock.
CAUTION: ALWAYS turn off the unit's motor BEFORE turning off the unit's water supply.
Serious damage could occur to the motor if the unit is run without water.
CAUTION: NEVER disconnect the high-pressure discharge hose from the machine
while the system is still pressurized. To depressurize the unit, turn off the motor, turn off
the water supply and squeeze the trigger 2-3 times.
OPERATING INSTRUCTIONS
Shut down
5