IO-Link Data Dictionary
10.02.03.00394
IO-Link Implementation
Vendor ID
Device ID
SIO-Mode
IO-Link Revision
IO-Link Bitrate
Minimum Cycle Time
Process Data Input
Process Data Output
Process Data
Process data In
Reserved
Reserved
PD in byte 0
Device Status
SP2 (part present)
SP1 (air saving function)
PD in byte 1
SP3 (part detached)
CM-Autoset
Reserved
PD in byte 2
Errors High-Byte
PD in byte 3
Errors Low-Byte
PD in byte 4
Warnings High-Byte
PD in byte 5
Warnings Low-Byte
PD in byte 6
Vacuum High-Byte
PD in byte 7
Vacuum Low-Byte
PD in byte 8
Reserved
PD in byte 9
Reserved
PD in byte 10
Reserved
PD in byte 11
Reserved
PD in byte 12
Reserved
PD in byte 13
Reserved
PD in byte 14
Reserved
PD in byte 15
Reserved
Process data Out
Vacuum
Blow-off
Setting Mode
PD out byte 0
CM-Autoset
Reserved
PD out byte 1
Input Pressure
PD out byte 2
Reserved
Profile Set
PD out byte 3
Reserved
ISDU Parameters
ISDU Index
Subindex
dec
hex
dec
Identification
Device Management
Vendor name
16
0x0010
0
Vendor text
17
0x0011
0
18
0x0012
0
Product name
19
0x0013
0
Product ID
20
0x0014
0
Product text
21
0x0015
0
Serial number
22
0x0016
0
Hardware revision
23
0x0017
0
Firmware revision
240
0x00F0
0
Unique device identification
250
0x00FA
0
Article number
252
0x00FC
0
Production date
Device Localization
Application specific tag
24
0x0018
0
Function tag
25
0x0019
0
Location tag
26
0x001A
0
Equipment identification
242
0x00F2
0
Geolocation
246
0x00F6
0
Bits
0...3
4..5
6..7
0
1
2
3
4..7
0..7
0..7
0..7
0..7
0..7
0..7
0..7
0..7
0..7
0..7
0..7
0..7
0..7
0..7
Bits
0
1
2
3
4..7
0..7
0..7
0..1
2..7
Parameter
Size
0...32 bytes
0...32 bytes
0...32 bytes
0...32 bytes
0...32 bytes
9
bytes
2
bytes
4
bytes
9
bytes
14
bytes
3
bytes
1...32 bytes
1...32 bytes
1...32 bytes
1...64 bytes
1...64 bytes
234 (0xEA)
100280 (0x0187B8)
yes
1.1 (compatible with 1.0)
38.4 kBit/sec (COM2)
Access
Remark
ro
Reserved
ro
Reserved
00 - [green] Device is working optimally
01 - [yellow] Device is working but there are warnings
ro
10 - [orange] Device is working but there are severe warnings
11 - [red] Device is not working properly
ro
Vacuum is above SP2 & not yet below rP2
ro
Vacuum is above SP1 & not yet below rP1
ro
The part has been detached after a suction cycle
ro
Acknowledge that the Autoset function has been completed
ro
not used
Bit 0 = Short circuit at OUT2
Bit 1 = reserved
Bit 2 = reserved
Bit 3 = Measurement range overrun
ro
Bit 4 = reserved
Bit 5 = reserved
Bit 6 = reserved
Bit 7 = IO-Link communication interruption
Bit 0 = IO-Link startup check: data corruption
Bit 1 = reserved
Bit 2 = Primary voltage too low
Bit 3 = Primary voltage too high
ro
Bit 4 = Auxiliary voltage too low
Bit 5 = reserved
Bit 6 = reserved
Bit 7 = reserved
Bit 0 = General input pressure out of operating range
Bit 1 = reserved
Bit 2 = reserved
Bit 3 = reserved
ro
Bit 4 = reserved
Bit 5 = reserved
Bit 6 = reserved
Bit 7 = reserved
Bit 0 = Valve protection
Bit 1 = Evacuation time above limit
Bit 2 = Leakage rate above limit
Bit 3 = SP1 not reached in suction cycle
ro
Bit 4 = Free Flow Vacuum over SP2
Bit 5 = Primary Voltage US out of operating range
Bit 6 = reserved
Bit 7 = reserved
ro
System vacuum [mbar]
ro
ro
not used
ro
not used
ro
not used
ro
not used
ro
not used
ro
not used
ro
not used
ro
not used
Access
Remark
wo
Vacuum on/off
wo
Activate Blow-off
Vacuum on/off with continuous suction disabled
wo
(regardless of dCS parameter)
Perform CM Autoset function (teach permissible leakage and
wo
permissible evacuation time)
wo
not used
wo
Pressure value from external sensor [0.1 bar]
wo
not used
wo
Profile selection
wo
not used
Value
Access
Default Value
Range
-
ro
J. Schmalz GmbH
-
ro
Innovative Vacuum Solutions Internet address
-
ro
RECBi_MATCH_1C
-
ro
'RECBi_MATCH_1C
-
ro
RECBi 24V-DC MATCH 1-C Order-code
-
ro
000000001
-
ro
00
-
ro
1.0
-
ro
-
ro
10.02.03.00394
-
ro
M22
-
rw
***
-
rw
***
-
rw
***
-
rw
***
-
rw
***
J. Schmalz GmbH
Johannes-Schmalz-Str. 1, D 72293 Glatten
Tel.: +49(0)7443/2403-0
Fax: +49(0)7443/2403-259
7 ms
16 bytes
4 bytes
Remark
Manufacturer designation
Product name
Product variant name
Serial number
Hardware revision
Firmware revision
-
Unique ID
Order-number
Date code of production (month and year, month is letter coded
User string to store location or tooling information
User string to store location or tooling information
User string to store location or tooling information
User string to store identification name from schematic
User string to store geolocation from handheld device