Setting Mode Ejector 2
CM-Autoset Ejector 2
PD out byte 1
Input Pressure Ejector 1
PD out byte 2
Input Pressure Ejector 2
Profile Set Ejector 1
PD out byte 3
Profile Set Ejector 2
Reserved
ISDU Parameters
ISDU Index
Subindex
dec
hex
dec
Identification
Device Management
16
0x0010
0
Vendor name
17
0x0011
0
Vendor text
18
0x0012
0
Product name
19
0x0013
0
Product ID
20
0x0014
0
Product text
21
0x0015
0
Serial number
22
0x0016
0
Hardware revision
23
0x0017
1
Firmware revision Ejector 1
23
0x0017
2
Firmware revision Ejector 2
240
0x00F0
0
Unique device identification
250
0x00FA
0
Article number
Production date
252
0x00FC
0
Device Localization
24
0x0018
0
Application specific tag
25
0x0019
0
Function tag
26
0x001A
0
Location tag
242
0x00F2
0
Equipment identification
Geolocation
246
0x00F6
0
NFC web link
248
0x00F8
0
249
0x00F9
0
Storage location
253
0x00FD
0
Installation date
Parameter
Device Settings
Commands
System command
2
0x0002
0
Access Control
90
0x005A
0
Extended device access locks
Pin-Code NFC
91
0x005B
0
Initial Settings
69
0x0045
1
Blow-Off mode Ejector 1
69
0x0045
2
Blow-Off mode Ejector 2
75
0x004B
1
Output filter Ejector 1, switch-off delay for SP2
75
0x004B
2
Output filter Ejector 2, switch-off delay for SP2
Process Settings Ejector 1
Production Setup - Profile P0 Ejector 1
Air-Saving function
68
0x0044
0
78
0x004E
0
Disable continous sucking
Switchpoint 1 (SP1)
100
0x0064
0
101
0x0065
0
Resetpoint 1 (rP1)
Switchpoint 2 (SP2)
102
0x0066
0
103
0x0067
0
Resetpoint 2 (rP2)
106
0x006A
0
Duration automatic blow
107
0x006B
0
Permissable evacuation time
108
0x006C
0
Permissable leakage rate
119
0x0077
0
Profile name
Production Setup - Profile P1 Ejector 1
180
0x00B4
0
Air-Saving function
181
0x00B5
0
Disable continous sucking
Switchpoint 1 (SP1)
182
0x00B6
0
183
0x00B7
0
Resetpoint 1 (rp1)
Switchpoint 2 (SP2)
184
0x00B8
0
185
0x00B9
0
Resetpoint 2 (rp2)
186
0x00BA
0
Duration automatic blow
Permissable evacuation time
187
0x00BB
0
6
7
0..7
0..7
0..1
2..3
4..7
Parameter
Size
0...32 bytes
0...32 bytes
0...32 bytes
0...32 bytes
0...32 bytes
9
bytes
2
bytes
4
bytes
4
bytes
9
bytes
14
bytes
3
bytes
1...32 bytes
1...32 bytes
1...32 bytes
1...64 bytes
1...64 bytes
1...64 bytes
1...32 bytes
1...16 bytes
1
byte
1
byte
2
bytes
1
byte
1
byte
2
bytes
2
bytes
1
byte
1
byte
2
bytes
2
bytes
2
bytes
2
bytes
2
bytes
2
bytes
2
bytes
0...16
bytes
1
byte
1
byte
2
bytes
2
bytes
2
bytes
2
bytes
2
bytes
2
bytes
Vacuum on/off with continuous suction disabled
wo
(regardless of dCS parameter)
Perform CM Autoset function (teach permissible leakage and
wo
permissible evacuation time)
wo
Pressure value from external sensor [0.1 bar]
wo
Pressure value from external sensor [0.1 bar]
wo
Profile selection Ejector 1
wo
Profile selection Ejector 2
wo
not used
Value
Access
Default Value
Range
-
ro
J. Schmalz GmbH
-
ro
Innovative Vacuum Solutions Internet address
-
ro
RECBi_MATCH_2C
-
ro
RECBi_MATCH_2C
-
ro
RECBi 24V-DC MATCH 2-C Order-code
-
ro
-
ro
-
ro
-
ro
-
ro
-
ro
10.02.03.00394
-
ro
-
rw
-
rw
-
rw
-
rw
-
rw
http://...
rw
https://myproduct.schmalz.com/#/
https://...
-
rw
-
rw
5, 129, 131,
165, 167,
wo
168, 169
0-255
rw
0-999
ro
0-2
rw
0-2
rw
0-999
rw
0-999
rw
0-2
rw
0-1
rw
999 > SP1
rw
> rP1
SP1 > rP1
rw
> SP2
rP1 > SP2
rw
> rP2
SP2 > rP2
rw
>= 10
100-9999
rw
0-9999
rw
0-999
rw
-
rw
0-2
rw
0-1
rw
999 > SP1
rw
> rP1
SP1 > rP1
rw
> SP2
rP1 > SP2
rw
> rP2
SP2 > rP2
rw
>= 10
10-9999
rw
0-9999
rw
Manufacturer designation
Product name
Product variant name
000000001
Serial number
00
Hardware revision
1.0
Firmware revision
1.0
Firmware revision
-
Unique ID
Order-number
M22
Date code of production (month and year, month is letter coded
***
User string to store location or tooling information
***
User string to store location or tooling information
***
User string to store location or tooling information
***
User string to store identification name from schematic
***
User string to store geolocation from handheld device
Web link to NFC app (base URL for NFC tag)
***
User string to store storage location
***
User string to store date of installation
0x81 (dec 129): Reset application
0x83 (dec 131): Back to box (IO-Link-Communciation will be stopped, restart by
power cycle is needed)
-
0xA5 (dec 165): Calibrate all vacuum sensor
0xA7 (dec 167): Reset erasable counters
0xA8 (dec 168): Reset voltages min/max
0xA9 (dec 169): Reset vacuum min/max
Bit 0: NFC write lock
Bit 1: NFC disable
Bit 2: Not used
0
Bit 3: reserved
Bit 4: IO-Link event lock (suppress sending IO-Link events)
Bit 5-7: Not used
0
Pin-Code for NFC write
0 = Externally controlled drop-off
0
1 = Internally controlled drop-off – time-dependent
2 = Externally controlled drop-off – time-dependent
0 = Externally controlled drop-off
0
1 = Internally controlled drop-off – time-dependent
2 = Externally controlled drop-off – time-dependent
10
Unit: 1ms
10
Unit: 1ms
0 = not active (off)
1
1 = active (on)
2 = active with supervision (onS)
0 = off,
0
1 = on
750
Unit: 1mbar
600
Unit: 1mbar
550
Unit: 1mbar
540
Unit: 1mbar
200
Unit: 1ms
Unit: 1ms
2000
no evacuation time warning if set to 0
Unit: 1mbar/s
250
no leakage rate warning if set to 0
***
Name of profile
0 = not active (off)
0
1 = active (on)
2 = active with supervision (onS)
0 = off,
0
1 = on
750
Unit: 1mbar
600
Unit: 1mbar
550
Unit: 1mbar
540
Unit: 1mbar
200
Unit: 1ms
Unit: 1ms,
2000
no evacuation time warning if set to 0
Remark