CHECK THE GENERATOR SURROUNDINGS:
WARNING:
Make sure you review each warning in order to prevent re hazards. Keep the surroun-
ding area clear of ammables or other hazardous materials. Keep the generator at least 3
feet (1 meter) away from all buildings and or other structures. Only operate the genera-
tor in a dry, well-ventilated area. Keep the exhaust pipe clear of all foreign objects. Keep
the generator away from open ames. Do not smoke in close proximity to the generator.
Keep the generator on a at and level surface. Do not attempt to block the generator air
vents with any paper or other material/objects.
BATTERY INSTALLATION (ELECTRIC STARTER MODEL):
The recommended battery capacity is 12V -24AH
WARNING:
Follow the instructions very carefully failing to do so may result in injury and or death.
Only use the recommended battery capacity. Ensure that the KEY/SWITCH is in the
"STOP" position prior to connecting or disconnecting the battery. Always check to
ensure that the terminals are connected correctly. Positive (+) Cable to Positive (+)
Terminal, Negative (-) Cable to Negative (-) terminal.
RED CABLE: Positive (+) Terminal / BLACK CABLE: Negative (-) Terminal.
Please note that the generator will not start if the connection of the battery is done
incorrectly. Ensure that you securely tighten the nuts and bolts on the battery terminals.
Disconnect the battery cables from the terminals when charging the battery. Please note
that when charging the battery, we recommend a "TRICKLE/SLOW" charge. This will pro
long the life of the battery.
HOW TO INSTALL BATTERY (See"OPTIONAL PARTS")
40
GROUNDING THE GENERATOR:
When grounding the generator connect the grounding lug of the generator to the
grounding spike.
If such grounding conductor or ground electrode is unavailable, connect the grounding
lug of the generator to the grounding terminal of the electric tool or appliance.
GROUNDING SPIKE
ENGINE SWITCH
CONTROL PANEL
IB-G5800
KEY SWITCH
USB SOCKET
(ELECTRIC STARTER)
CONTROL PANEL
IB-G6500ET (400V)
12V OUTPUT
GROUND TERMINAL
DIGITAL
AC SOCKET
METER
12V OUTPUT
GROUND TERMINAL
DIGITAL
AC SOCKET
METER
AC PROTECTION
GROUND TERMINAL
CIRCUIT
BREAKER
CIRCUIT
BREAKER
41