AC CURRENT
Range
200 mA
20 A
Overload protection: 250 RMS
Use the automatic recovery fuse after the external fault disappears, the
fuse returns to normal and the multimeter can be used normally
Maximum voltage drop measurement: 200 mV
Maximum input current: 20 a (test time must be between 10 seconds)
Frequency response: (40 – 1 000) Hz (For standard sine wave and
triangular wave).
Display: True RMS (only as reference when over 200 Hz in other waves)
RESISTANCE (Auto-fluctuating)
Range
200
2 k
20 k
200 k
2 M
20 M
200 M
Overload protection: 250 v DC and AC peak value
NOTE
In range 200
the test probes must be short-circuited and measure the
resistance of the conductor and subtract the actual measurement.
ADVERTENCIA
For safety reasons DO NOT ENTER any voltage in the resistance range
Resolution
100 µA
10 mA
Resolution
0,1
1
10
100
1 k
10 k
100 K
Accuracy
(1,5% de rdg + 10 dgts)
(2,0% de rdg + 10 dgts)
Accuracy
(1,2% de rdg + 5 dgts)
(1,5% de rdg + 5 dgts)
(2,5% de rdg + 5 dgts)