The use of automatic recovery fuses, after eliminating the fault, causes the
fuse to return to normality and the multimeter can be used normally. No
need to change the fuse.
The 20 A range has a 20 A / 250 V fast blow fuse. Change the fuse according
to the specifications: 20 A, 250 V, FAST, Min. Interrupt Rating 20 000 A,
diameter 5 mm x 20 mm.
Uses a 6F22 9 V DC carbon-zinc battery (included).
WARNING
To avoid false readings which could lead to electric shock or personal injury,
change the battery as soon as the symbol ("
To prevent damage or injury, install only replacement fuses with the
specified amperage, voltage and interruption levels.
TO OPEN THE BATTERY COVER
To change the fuse, remove the screws from the support frame, remove the
multimeter from its case, remove the rear cover, replace the fuse with a new
one of the same sizes.
Reassemble the support frame, reinstall the screws.
Disconnect the test probes before opening the rear battery cover.
1. The battery and fuse should only be changed after the test probes are
disconnected and the device is switched off.
2. Loosen the screws with a suitable screwdriver and remove the lower part
of the housing.
3. The multimeter has a 9 V DC battery.
Remove the battery connector tips from the ends of a new battery and
reinsert the battery into the housing lid. Fix the tips of the new battery so
that they do not get stuck in the bottom of the housing.
TO DISPOSE OFF THE ARTICLE
Dear customer:
In case you wish to dispose of this item, you should keep in mind that many
of the components consist of materials with a value that can be recycled.
Please do not dispose of it in the household waste.
Ask your local authority where it can be recycled.
") appears.