User's Guide
7. CAlIBrAtION
The scale can be calibrated using the following procedure. For a more detailed method of calibrating the scale it will be necessary to
enter the secure Programming Menu. See detail in section 12.
The BR70 weighing indicator can calibrate using either metric or pound weights, depending on the weighing unit in use before calibra-
tion. The display will show either "kg" or "lb" to identify the weights expected.
PREOCEDURE
› Turn the power off.
› Turn the power back on, during the counting from 9 to 0 press the
› The display will show "CAL" for a few seconds. While it is showing "CAL" press the
Calibration section. The display will show "unLoAd".
› Remove any weight from the platform. After stable indicator on, press the
› The display will show last calibrate weight value, you can use
key to move active digit, use
calibration weight on the scale. Press the
› If the calibration is acceptable the display will show "PASS" and then return to normal. If an error message is shown try calibration
again as a disturbance may have prevented a successful calibration.
› If the problem persist then contact your dealer.
› After calibration the scale should be checked to verify the calibration and linearity is correct. If necessary repeat calibration, especially
be certain the scale is stable before accepting any weight.
8. ErrOr COdES
ERROR CODES
-----
Err1
Err2
Err4
Err5
Err6
Err9
26
key to change value), after you setting, press
key.
DESCRIPTION
RESOLUTION
Over range
Remove weight from the scale.
If the problem persist contact your dealer or Baxtran scale for assistance.
Date Setting Error
Enter date using correct format and reasonable values.
Format: yy:mm:dd
Time setting Error
Enter time using correct format and reasonable values.
Format: hh:mm:ss
Zero Setting Error
The scale was outside the normal zero setting range either when it was
turned on or when the
and try again. Use the
persist contact your dealer for assistance.
Keyboard short
Keyboard damaged
A/D out of range
The values from the A/D converter are outside the normal range. Remove
weight from the scale if overloaded, make sure the pan is attached. Indicates
the load cell or the electronics may be faulty. If the problem persist contact
your dealer for assistance.
Unstable, can't re-
When turn on the power, if internal counts is not stable, display will have "Err
turn to zero
9", please check the platform and load cell. If the problem persist contact your
dealer for assistance.
Indicator
key.
,
and
key.
,
,
, key input new calibrate weight value (use
key to sure, display will show "LoAd". Place the
key was pressed. Remove weight from the scale
key to set the display to zero value. If the problem
Model BR70
keys in sequence to enter the
,