7) DOOR OPEN ALARM
When the "GS" alarm input on the outdoor station has been unbalanced for more than 2 minutes, the device emits an optical signal
(the red and green led flashes alternately) to warn that the door has been left open.
Note: the open door signal is sent to all the indoor stations of the system; to stop the signal, close the door associated with it.
8) ANSWERING A CALL
1. When a visitor presses a button on the outdoor station, a call is forwarded to that User.
At the same time, the doorbell of the selected indoor station will ring.
2. The resident can press
to answer the call
3. During the call, the resident can press briefly
outdoor station); press and hold the same key to activate the 2nd output of the outdoor station.
Press briefly the key
to activate the output on the auxiliary relay, if present.
The call will be automatically closed 5 seconds after the door has been opened.
4. Press
to switch the view to an extension video camera, if present.
5. The resident may stop the call by pressing
9) CALLING THE CONCIERGE
When the indoor station is in Stand-By mode, the resident can call the concierge, if present, by pressing
Note: the address 200 must be assigned to the "concierge" indoor station.
10) MONITORING
1. Press
to monitor the outdoor station. If multiple outdoor stations have been installed, press again
access the next station.
2. During the call, the resident can press briefly
outdoor station); press and hold the same key to activate the 2nd output of the outdoor station.
Press briefly the key
to activate the output on the auxiliary relay, if present.
Monitoring will be automatically closed 5 seconds after the door has been opened.
3. During monitoring press
to communicate with the monitored device; press
the communication.
11) INTERCOMMUNICATING CALL
In Stand-By mode, briefly press
1. Press the
(UP) button to increase or
called. Press and hold the same button to quickly increase/decrease the number (min. 001 max. 200).
2. Then press the
(OK) button to start the call. The device will activate a feedback tone to signal the
call-in-progress status.
3. Press briefly
to close the page
12) VIDEO SETTINGS
When the device is in the active ringtone / Monitoring / Call-in-progress condition, press and hold
video settings menu.
1. Press
(DOWN) or
(UP) to select the parameter to be edited: BRIGHTNESS, CONTRAST or COLOUR
2. After choosing the parameter to be set, press
3. Press
(DOWN) and
(UP) to decrease or increase the value of the specific parameter (BRIGHTNESS, CONTRAST,
COLOUR) within a 1 to 10 range. To save the value, press
4. Press
to exit the menu. The device will exit the menu also if no operation is performed within 5 s.
13) TECHNICAL CHARACTERISTICS
Operating voltage
Maximum operating voltage
Absorption during operation
Absorption during stand-by
Dimensions (L x H x D)
LCD size
Resolution
TO DOWNLOAD THE COMPLETE MANUAL OF THE 2-WIRE SYSTEM, SCAN THE QR CODE SHOWN ON THE DRAWINGS PAGE
to open the door/gate (1st high energy output on the
.
to open the door/gate (1st high energy output on the
to access the intercommunicating call:
(DOWN) to decrease the number of the address of the indoor station to be
(OK). The cursor bar will switch from yellow to green
(OK); the next parameter will be displayed automatically.
30V
DC
32V
DC
170 mA max @ 30 V
DC
7 mA max @ 30 V
DC
120 x 180 x 19.5 mm
4.3 inches
480 x 272 pixels
to
again to end
to access the
Operating temperature
Maximum altitude
Maximum number of devices that can be installed
Installation
Protection rating
Environmental class as per EN 62820-1-1
Call interface
INDOOR: 200
Concierge call interface
INDOOR: 001
DOWN
OK
UP
Intercommunicating Call
BRIGHTNESS
5/10
DOWN
OK
UP
BACK
Video BRIGHTNESS setting interface
BRIGHTNESS
5/10
From -10 °C to +55 °C
2000 m a.s.l.
4
On vertically installed flush-mounted boxes,
using the support provided
IP20 (IP40 when installed)
CLASS III
BACK