SPECIFICATIONS
Frequency range of operation................................................................. 50 MHz - 60 GHz
Frequency response .................................................Shaped (Occupational / Controlled)
ICNIRP (2020)
FCC [NCRP] OET65 (1997)
Canada Safety Code 6 (2015)
IEEE C95.1 (2005)
Sensor polarisation ................................................................................................. Isotropic
Isotropy
......................................................................................................................... ± 3 dB
1
Probes .................................................................. 3 orthogonal E and 3 orthogonal H field
Result type ..................................................................Time-averaged RMS power density
Calibration interval ................................................................................................... 2 yearly
CW damage level ..................................... 26 dB above Standard / 40 000 % of Standard
Battery type ................................................................... 2 x 1.5 V Size AAA(LR03) Alkaline
Battery life ..................................................................... 6 months - 1 year (average usage)
Weight (incl. batteries) ....................................................................................0,25 lb, 115 gr
Dimensions ................................................................................................146 x 26 x 42 mm
IEC 60529 rating ..........................................................................IP64 (battery cap closed)
Temperature range ........................................................................................ -20 °C to 50 °C
Fall detection ...................................................................................... 3 axis accelerometer
Frequency response
Frequency
50 MHz — 10 GHz
10 GHz — 27 GHz
27 GHz — 40 GHZ
40 GHz — 60 GHZ
1.
Isotropy is the measure of deviation from the mean over the sphere at a frequency, below 6 GHz
2.
The response is a combined E & H field deviation from the relevant standard as is reported by the exposure indicators with
planar wave illumination on the rear-side of the device, both vertically & horizontally polarised.
3.
Positive values indicate conservative readings i.e. early warning.
4.
NB! Only use the device in this frequency range, measurements outside of this frequency range will not be accurate and
cannot be guaranteed.
5.
H field contributions assessed from 50 MHz — 1 GHz only.
6.
Not suitable for Radar applications.
2
ICNIRP
2,0 ± 3,0 dB
1,0 ± 4,0 dB
6,0 ± 4,0 dB
7,5 ± 5,5 dB
FCC/NCRP
2,5 ± 3,5 dB
1,0 ± 4,0 dB
6,0 ± 4,0 dB
7,5 ± 5,5 dB
Canada SC6
1,0 ± 4,0 dB
1,0 ± 4,0 dB
6,0 ± 4,0 dB
7,5 ± 5,5 dB