Descargar Imprimir esta página

Trust START-LINE ACM-250-LD Manual Del Usuario página 10

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 29
ACM-250-LD BUILD-IN DIMMER
EN
6B.
This is the technical installation schematic of the ACM-250-LD with two wall-switches (hotel/
stairwell circuit).
6C.
This is the technical installation schematic of the ACM-250-LD with one wall-switch.
7. Enable mains power
Switch the mains power ON before proceeding with the installation.
Make sure no stripped parts of wires are touched after this step.
The LED indicator on the receiver will light up for a few seconds when voltage is applied.
8A. Activate pairing mode
Press for about 1 second (with a pointed object) on the Connect button to activate the pairing mode.
The pairing mode will be active for 12 seconds and the LED indicator on the receiver will flash slowly.
8B. Send an ON signal
While the LED indicator flashes, press the ON button on a Trust Smart Home transmitter to pair the
transmitter to the ACM-250-LD. (Or activate a Trust Smart Home sensor).
8C. Pairing confirmation
The LED on the module will blink fast in order to confirm that the code is stored. The receiver can
store up to 32 different transmitter codes in its memory. The memory is retained when the receiver is
installed elsewhere or when there is a power failure.
9. Wireless control
Send with the transmitter an ON signal to turn the light on wirelessly.
Send with the transmitter an OFF signal to turn the light off wirelessly.
With the AYCT-202, the lighting can be dimmed with the dimming buttons.
Consult the manual of the transmitter for more information.
The existing wall switches which are used to control the connected lighting can still be used.
2

Publicidad

loading

Este manual también es adecuado para:

71213