STEP 4: CONNECTION OF PE PIPES TO
THE MAIN UNIT
The main unit has a waste water outlet, a purified water outlet and a tap water inlet.
These correspond to the three PE pipes.
1. Remove the protective silicone plugs from
the inlet and outlets of the main unit
(Fig. 12-a).
2. Insert the red PE sewage pipe into the
quick-connect fitting of the water outlet of
the drain (fig. 12-b). The other end of the PE
sewage pipe is connected to the clamp.
3. Insert the white PE pipe from the tap water
into the quick-connect fitting on the tap
water inlet. The other end of the PE pipe
from the tap water is connected to the
3-way valve.
4. Insert the blue PE purified water pipe into the quick-connect fitting on the purified
outlet. The other end of the purified water PE pipe is connected to the tap.
5. Secure each of the PE pipes with the safety clips (see step "How to use the quick
connectors") (Fig. 9-c).
STEP 5 LEAKAGE CHECK
NOTE
Do not connect the main unit to the mains at this time. Always check for leaks before
connecting the product to the mains.
1. Turn off the tap.
2. Open the 3-way valve and the shut-off
valve of the water supply (Fig. 13).
3. Check all connection points for leaks.
4. Shut off the water supply with the water
supply shut-off valve if leaks are detected.
STEP 6: CONNECT THE TAP POWER CABLE
Connect the tap to the equipment: Insert the power cable that is attached to the
reverse osmosis tap into the connector on the back of the housing.
Tap connector
50
3-way valve
Válvula de 3 vías
Válvula de cierre
Shut-off valve
System connector
EN