Descargar Imprimir esta página

STAR Water Systems S2000 Manual De Instrucciones página 14

Ocultar thumbs Ver también para S2000:

Publicidad

Idiomas disponibles

Idiomas disponibles

PIPING
1. Cut and dry-fit the pipe and fittings as required
for 1-in (DN25) diameter discharge pipe (may
be reduced to 3/4-in (DN20) diameter if local
code allows it).
2. While dry-fitting the discharge pipe, position
and mark the location of the pump unit
discharge fitting.
3. Cut and dry-fit 1-1/2-in (DN40) vent pipe as
required to ensure that the vent pipe does not
interfere with other components. Make the
connection to the pump unit with the provided
street elbow. A 2-in x 1-in 90º discharge fitting
has been provided.
4. Temporarily set the toilet in place to check that
there is no piping interference. Remove the
toilet and set it aside.
5. Clean, prime and solvent weld the discharge
piping and pump unit discharge fitting.
to discharge fitting, ensure that none gets into
the check valve assembly. Pay close attention
to the proper alignment of the discharge fitting
previously marked.
6. For markets requiring a pipe vent, clean and
solvent weld the vent piping as required for
proper venting.
7. Optional carbon filter vent:
For markets where a carbon filter vent is
allowed, please replace the carbon filter
1. Connect the desired discharge pipe from other fixtures
to the side inlet(s) of the Powerflush Optima.
Proper venting is required
When applying solvent weld
periodically to keep ventilation functioning
properly.
Note: Adding other bathroom fixtures: The
Powerflush system is designed to accept
additional bathroom fixtures utilizing the two side
inlets. These inlets can be attached using the 2-in
MPT (outside diameter) or the 1-1/2-in (DN40)
slip (inside diameter). These inlets must have the
inner portion drilled out using a 1-3/4-in (44mm)
hole saw. This is to ensure there is no leaking
problems from inlets not in use. When utilizing
side inlets, install a check valve on the incoming
line.
has been drilled out, remove burrs and rough
edges to avoid the potential for clogging.
1-1/2" stack vent
2" NPT Outside
1-1/2" Slip Inside
1
14
Once the side inlet opening
1" Discharge
2" NPT Outside
1-1/2" Slip Inside

Publicidad

loading

Este manual también es adecuado para:

S2002