7. Hz% Botton
When you measure the Hz%, pressing this button will switch the Digital
multimeter between Hz function and duty cycle function.
When you measure the ACV, pressing this button will switch the Digital
multimeter will show the frequency of the AC voltage.
8. Function/Range Switch
This switch can be used to select desired function and range.
9. "A" Jack
Plug-in connector for the red test lead for Current (400 mA ~ 10 A)
measurements.
10. "COM" Jack
Plug-in connector for black (negative) test lead.
11. "INPUT" Jack
Plug-in connector for the red test lead for all measurements except
current ( > 400 mA) measurements.
5. SPECIFICATIONS
Accuracy is guarantied for 1 year 23 °C 5 °C less than 80% RH
DC VOLTAGE (Auto ranging)
Range
400 mV
4 V
40 V
600 V
Input Impedance: 10 M
Overload Protection: 600 V DC or 600 V AC RMS
Max. Input voltage: 600 V DC
Resolution
0.1 mV
1 mV
10 mV
1 V
(200 mV range: 250 V DC / AC RMS)
Accuracy
(0.8% of rdg + 5 dgts)
(0.8% of rdg + 3 dgts)
(1.0% of rdg + 5 dgts)