AC VOLTAGE (Auto ranging)
Range
4 V
40 V
600 V
Input Impedance: 10 M
Frequency Range: 40Hz ~ 400Hz
Overload Protection: 600 V DC or 600 V AC RMS
Response: True-RMS
Max. Input voltage: 600 V AC RMS
TEMPERATURE
Range
- 40 ºC – 1 370 ºC
- 40 ºF – 2 000 ºF
NOTE: Different temperature sensors are configured in different
temperature test ranges, and normal temperature sensors are
provided for standard configuration.
DC CURRENT
Range
400 µA
4 000 µA
40 mA
400 mA
4 A
10 A
Resolution
1 mV
10 mV
1 V
Resolution
Accuracy
1 ºC
-40 ºC
150 ºC
1 ºF
-40 ºF
320 ºF 2 000 ºF (2.5% + 4)
Resolution
0.1 µA
1 µA
10 µA
100 µA
1 mA
10 mA
Accuracy
(1.0% of rdg + 8 dgts)
(1.2% of rdg + 8 dgts)
150 ºC: (2.5% + 4) about
1 370 ºC (2.5% + 4)
302 ºF: (2.5% + 4) about
Accuracy
(1.2% of rdg + 8 dgts)