I.
Separator centrifuge
3.2.
Preparation for operation
POSITIONING OF THE UNIT
The ambient temperature must not exceed the range of 10-40°C, and the relative
humidity should not exceed 95%. Place the unit in a way that ensures good air
circulation. Maintain a minimum safety distance of at least 1m from each wall of the
unit. Keep the unit away from any hot surfaces. Always operate the unit on a level,
stable, clean, fireproof and dry surface and out of the reach of children and persons
with impaired mental, sensory and intellectual functions. Place the unit in such a
way that the mains plug can be reached at any time. Ensure that the power supply
to the unit corresponds to that specified on the identification plate!
ASSEMBLY OF THE DEVICE
The machine is delivered mostly assembled - only the raw material hopper inlet (A)
and the processed raw material outlet need to be installed.
1. The inlet of the raw material hopper (A) should be screwed to the inlet housing
at the opening, using the screws attached to the ends of the opening in the
housing.
2. Screw the pipe adapter (a) with the collar (b) to the outlet from the turbine
housing (G):
3. Connect the separator centrifuge housing (c) to the long tube bent at the end
(d):