NOTE
1. If the measured current is unknown beforehand, set the functions
2. If the LCD shows "OL", means it is above range. Switch the functions
MEASURING DC CURRENT
• Insert the black test probe into the "COM" connector and the res one
• Set the function switch into the adequate DC current range. Connect
NOTE
1. If th measured current is unknown beforehand, set the functions switch
2. If the LCD shows "OL", means it is above range. Switch the functions
3. When measuring 20 A. The continuous measurement of high current
MEASURING AC CURRENT
• Insert the black test probe into the "COM" connector and the red one
• Set the functions switch into the adequate AC current range. Connect
NOTE
1. If the measured current is unknown beforehand, set the functions
2. If the LCD shows "OL", means it is above range. Switch the functions
3. Pay attention when measuring 20 A. The continuous measurement of
MEASURING RESISTANCE
• Insert the black test probe into the "COM" connector and the red one
Disconnect the test probes before opening the batteries back cover.
1. Changing battery and fuse shall only be carried out after the test
2. Using the right screwdriver, loosen the screws and remove the lower
3. The multimeter uses a 9 V DC battery. Remove the tips from the
TO DISPOSE OFF THE ARTICLE
Dear customer:
In the event you wish to dispose of this article, keep in mind that many of
the components consist in valuable materials that can be recycled.
Please do not throw it away with domestic garbage.
Ask the local authority where to recycle.
shows.
switch in the highest range. Then, switch into the adequate range
according to the value shown.
switch into a higher range.
into "mA" connector. (Maximum 200 mA) or insert the red one into the
"20 A" connector (maximum 20 A).
the test probes through the circuit to be measured. The current value
and polarity in the point to which the red probe is connected is shown
in the LCD.
in the highest range. Then, switch into the adequate range according to
the value shown.
switch into a higher range.
may heat the circuit, affect precision and damage the multimeter.
into the "mA" connector (maximum 200 mA), or insert the red test
probe into "20 A" connector (maximum 20 A).
the test probes through the circuit being tested.
switch in the highest range. Then, switch into the adequate range
according to the value shown.
switch into a higher range.
high current may heat the circuit, affect precision and damage the
multimeter.
into "INPUT" connector.
probes are disconnected and the device id off.
part of the housing.
battery connector from the terminals in. the new battery. Reinsert
the battery in the housing cover. Arrange the new battery tips to
avoid getting jammed in the housing bottom.
• Set the functions switch into the adequate resistance range. Connect
the test probes through the resistance to be measured.
1. If the resistance value measured exceed the maximum value of the
selected range, the LCD will show "OL". Therefore, set the functions
switch in a higher range. When resistance is above 1 M
multimeter will take a few seconds to stabilize. This is normal for high
resistance readings.
2. When the input terminal is in the open circuit, it shows overload.
3. When measuring resistance in line, double check the power supply is
off and all the capacitors are completely released.
MEASURING CAPACITANCE (automatic range)
• Insert the red test probe into "INPUT" terminal and the black one into
the "COM" connector.
• Set the functions connector into 20 mF range. connect the test probes
to the capacitor being measured. (NOTA: Polarity of the red test probe
is "+").
1. Before measuring, it is possible the LCD display is not showing zero.
The residual reading gradually decreases. This can be ignored.
2. When reading a very large capacitance, LCD will show some instability
value.
DIODE AND CONTINUITY TEST
• Insert the black test probe into terminal "COM" and the red one into the
"INPUT" connector. (NOTE: Polarity of the red test probe is "+").
• Set the functions switch into "
" range. Connect the test probes
into the diode to be measured. The reading is an approximation to the
positive drop of the diode voltage.
• Connect the test probes into two pints in the measured circuit. If the
buzzer rings, resistance is lower than 50
MEASUREMENT OF hFE
• Set the range knob in hFE.
• Verify the transistor type is NPN or PNP. Insert the emitter, base and
collector in the adequate connector.
, the
approximately.