Safety instructions (to be followed at any time)
Rotate the safety valve handle
once a month. The valve
works well if there is water
flowing out, otherwise check
for blocking and replace the
safety valve if necessary.
The water drain pipe shall be in connection with the
atmosphere, it shall not be blocked; the water drain pipe
connected to a safety valve shall be installed in a frostless
environment with an continuous downwards inclination.
The appliance contains fluorinated greenhouse gases.
Chemical name of the gas: R134a/ 0,46Kg
Fluorinated
hermetically sealed equipment.
Global Warming Potential(GWP) : 1430
If needed, please refer to the wiring diagram on page 23.
The method of connection about the appliance to the
electrical supply refer to page 21.
In accordance with safety rules, a safety valve(8bar,G1/2F)
must be installed on the tank. For France, we recommend
hydraulic safety units fitted with a membrane with the NF
marking. The rated pressure of the safety valve shall not
exceed 0.8MPa.
greenhouse
5
5
Water
heaters
equipped with a dedicated
power
line
current circuit breakers. The
action
current
exceed 30 mA;
gases
are
shall
be
and
residual
shall
not
contained
in