Descargar Imprimir esta página

Haier HP150M5 Manual De Operación E Instalación página 79

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 31
Description of the pictograms
Symbol
Description
Power ON/OFF switch
Working mode selection
Confirm button
Timer adjust
Boost mode. Heat pump and auxiliary power are
activated at the same time.
Auto mode
-Optimised management of the heat pump and the electrics
for guaranteed comfort;
- Prior using heat pump;
- If compressor works more than the default 8 hours , start
the auxiliary power;
- The compressor maximum continuous working time( )
can be adjust in the installer settings.
ECO (off-peak) mode
- In this mode ,priority using heat pump;
- In two ways using heat pump,should set in the installer
settings;
1- timer refer to LP parameter;
2-switch signals by power companies.
Electric heating mode
- In this mode, the electric heating function is turned on, and
the electric heating function remains effective.
- This function ensures hot water supply when the heat pump
is not working properly;
Holiday mode
- According to the vacation dates in advance to prepare
hot water;
- For example, you leave home for vacation on January 1st and
return home on January 5th. The date shall be set as
(5-1) =4 days, and corresponding temperature shall also be set.
The heat pump will start heating on 00:00 o'clock of January
4th automatically.
21